Generating set grounding
The generating set must be properly connected to an appropriate ground. It helps prevent electri-
cal shock if a ground fault condition exists in the generating set or in connected electrical devices,
especially when the unit is equipped with a wheel kit.
Proper grounding also helps dissipate static electricity, which often builds up in ungrounded de-
vices.
A ground terminal has been provided on the generating set.
For remote grounding, connect of a length of heavy gauge (4mm2) copper wire between the gen-
erating set ground terminal and a copper rod driven into the ground.
Local electrical codes may also require proper grounding of the unit. We strongly recommend that
you consult with a qualified electrician for grounding requirements in your area.
Battery connection (If applicable)
Remove the battery maintenance cover, connect the battery terminal to the motor terminal, and
reinstall the maintenance cover.
Starting the generating set
Pull the starter handle 6-8 times to pre-fill fuel system before initial operation or removal from
long term storage. Failure to do so could result in bad starting experience.
① Perform operating checklist (refer to chapter ''Operating checklist'') and remove all loads.
② (Applicable types) Turn the ventilation knob of fuel cap to the "ON" position to ensure fuel
flow.
③ (Suitable for hand start) Cold start: Turn the combination switch to "CHOKE" position to shut
off the choke.
Warm start: Turn the combination switch to "RUN" position, if not started, please turn the com-
bination switch to ''CHOKE" position before restarting.
RUN
OFF
STOP
④ Manual start:
Check starter cord conditions before operat-
ing. Have it replaced immediately by local au-
thorized dealer if cord is frayed.
1. When starting engine, grasp the recoil starter handle and pull slowly until resist-
ance is felt.
Then pull rapidly to avoid kickback. When pulling the recoil starter, Firmly grasp the
generator to avoid tumble of generator or personal injury caused by tumble.
9
CHOKE
WWW.BORMANNTOOLS.COM
Electrical Shock
Failure to properly ground the generating set
can result in electric shock.