Control Panel
Overload Indicator (red)
When the overload indicator is on, it indicates that the generating set is overload and then
the AC protector works. It will stop the output of generating set to protect the electric equip-
ment and the generating set itself. At this time, the running indicator (green) is off and the
overload indicator (red) is on, but the engine is still in running state.
When the generating set has no output and the overload indicator is on, please take the
following steps:
1. Lower the total power of the connected electric devices to the rated output range of
generating set.
2. Check the air intake for impurities and check the control parts for abnormal situation.
Handle immediately if necessary.
3. Press the reset button.
Running indicator (green)
The running indicator lights up when generating set starts and has normal output.
Oil alarm lamp (yellow)
When the oil level drops below the lower limit, the oil protection system will stop the engine
automatically and oil alarming lamp will blink by pulling the recoil starter. The engine will not
run until the oil has been filled to the proper level.
Note: If engine flames out or fails to start, turn the combination switch to "RUN'' posi-
tion and then pull the recoil starter. If the oil alarming lamp lights up, it shows lack of oil.
Please add appropriate oil and restart the engine.
5
WWW.BORMANNTOOLS.COM
❶ Power indicator
❷ Overload indicator
❸ Running indicator
❹ Oil alarm lamp
❺ Fuel display
❻ USB port
❼ Energy-saving switch
❽ DC Circuit breaker
❾ 12VDC
❿ AC Circuit breaker
⓫ AC American-type three-hole receptacle
⓬ Ground terminal
⓭ Parallel kit terminal
⓮ AC 20A Circuit breaker
⓯ AC output receptacle
⓰ Reset button
⓱ Push-button start
⓲ Circuit breaker
⓳ T-type DC output