BorMann Pro BGB2035 Manuel D'utilisation page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Reset button
The reset button is used to restore output if an overload occurs. To restore output, reduce the loads
and press the reset button.
Energy-saving switch
When the energy-saving switch is in "ON" position, the energy saving equipment controls the engine
rotate speed according to the connected loads. There will be good fuel consumption and low noise.
When the energy-saving switch is in "OFF" position, the engine will always run in rated rotate speed no
matter it is connected to the loads or not.
Note: Please set the energy-saving switch to ''OFF" position when connect to air compressor, sinking
pump etc., because these equipments need large starting current.
Grounding terminal
The grounding terminal is designed to prevent electric shock by connecting it to the grounding wire. The
generating set must be properly grounded before operation.
Combination switch (STOP/OFF/RUN/CHOKE)
RUN
Note: One-button start and remote control start, no function of manually close for
the choke.
CHOKE
STOP: The stop position of the generator.
OFF
Note: After the generating set is unloaded, please run for 3 minutes at no load to sta-
bilize the temperature, then stop the generating set.
STOP
OFF: Fuel off without stop. This position can run out of the remaining fuel and Improve
the reliability of the generating set.
Note: If you do not plan to use the generator in the near future, please use this func-
tion, or drain the fuel inside the carburetor through the carburetor drain bolt.
RUN: The generating set operates normally.
CHOKE: Close the choke.
Note: Turn to choke position to start when engine is cold, and turn to RUN position to
start when engine is hot.
Circuit breaker
When the generator is overloaded or overheated for a long time, the thermal protec-
tor works. Under protected, please reduce the load or run it for a few minutes without
load. Press the thermal protector button, then output recovers.
Note: The thermal protector is Influenced by factors, such as operation current and
ambient temperature, so the protection time varies.
Parallel kit terminal
It is used for parallel operation with another inverter (parallel kit sold separately).
6
WWW.BORMANNTOOLS.COM