Stopping the generating set
① Remove the connectors of all electric equipment from the generating set
panel.
NEVER stop the engine with electrical devices connected and running.
② Turn the combination switch to the "stop" position, the generator stops
operation.
Wireless remote shutdown (if applicable)
Press and hold the ''OFF" button for at least 0.3 seconds to stop the generator. After the generator stops , turn the combination switch to the "stop'' position.
Note: When the control distance is shortened or the indicator light is on but the remote control function is not available, replace the battery. Contact your local
dealer for more information.
One-button start-stop (if applicable)
Press the start-stop button to turn off the generator. After the generator shutdown, turn the combination switch to "stop'' position.
③ (Applicable types)
After the generator stops and cools down, turn the fuel tank cap ventilation knob to "OFF" position.
Parallel operation (If applicable)
During parallel operation, energy-saving switches of generating sets should be in the same position.
① Connect one generating set to other generating set(s) in parallel. Use the parallel kit to make the parallel connection (the parallel kit needs to be purchased
separately).
② Insert the plug of the parallel kit into the parallel socket on the panel, and start the generators In turn. Make sure that the output indicator of each generator
is in normal state (green).
③ Connect the plug of electric devices to the
AC sockets of the parallel kit.
④ Run the electric devices.
12
If the generator will not be used for a long time, please turn the combination switch to
the "off" position. After the fuel in the carburetor oil cup runs out and the generator
automatically shuts down, turn the knob to the "stop" position. If the combination
switch knob is not turned to the "stop" position, there is a risk of fuel leakage. And
the battery will be undercharged after a long time placed, resulting in failure to start
the generator.
WWW.BORMANNTOOLS.COM
When connecting, please connect the plug to the panel socket of the same color.
The total power of electric devices cannot exceed the rated power of generating set.
The manufacturers of electric devices or tools always list the rated power of similar
models or serial number.
When slightly overload, the load indicator flashes continuously, which may shorten
the life of the generator. When severe overload, the load indicator light keeps on,
which may cause damage to the generator.