INsTALLATIoN
Installation
f Rotate the internal panel cover 45° anti-clockwise.
f Remove the cover.
f Use the knurled screws included in the standard delivery
to secure the internal panel base plate to the wall mount
casing.
f Fit the internal panel cover on the base plate with a 45°
offset.
f Rotate the internal panel cover 45° clockwise.
Note
Only open the internal panel just before commissioning.
34
| LWE 40
Internal sound insulation panel
1 Spring button
f Press and hold the spring button underneath the internal
sound insulation panel.
f Pull the bottom of the internal sound insulation panel away
from the wall mounting frame.
f Lift the internal sound insulation panel up and off the two
stop bolts.
2
1 Sealing tape
2 Wall mounting frame
f Affix the sealing tape included in the internal panel standard
delivery around the back of the wall mounting frame and into
the wall mounting frame. The sealing tape must be in contact
at the side with the back-facing tabs of the wall mounting
frame.
1
1
www.stiebel-eltron.com