EN
E-PAK 500 DX Hybrid
Material recycling
Sound level
5.3.2
Motor
Voltage and
power
frequency
(kW/hp)
(V)/(Hz)
E-PAK 500 DX HYBRID
12.5
230/50
13
400/50
15.3/20
208/60
14.5/19
230/60
15.3/20
440/60
15.3/20
460/60
15.3/20
575/60
26
Electrical data
'Table 5-2: Electrical data' contains electrical data for the E-PAK 500 DX Hybrid
high vacuum units. For the location of the motor and starter cable areas (items
Z, V and X in the table), see Figure 18 and Figure 19.
Table 5-2: Electrical data
Nom.
F1
F2 & F3,
current
Recom.
slow (A)
(A)
mains
fuses,
slow (A)
47.5
50
6
27
35
6
55.0
60
6
49.6
60
6
27
35
6
26.0
35
6
20.4
25
6
E-PAK 500 DX HYBRID
Approximately 95 percent per weight
<70 dB(A)
F4,
F5 & F6,
S1F Over-
slow (A)
fast (A)
load relay
setting
(A)
4
1
27.4
4
1
15.6
4
1
31.8
4
1
28.6
4
1
15.6
4
1
15.0
4
1
11.8
Min.
Cable
Cable
cable
area
area
area to
inside
inside
motor
starter
starter
(mm
) Z
(mm
) V
(mm
2
2
6.0
2.5
16.0
2.5
2.5
6.0
6.0
4.0
16.0
6.0
4.0
16.0
2.5
2.5
10.0
2.5
2.5
10.0
2.5
2.5
10.0
) X
2