en
46 | ACS 511 | Initial commissioning
6.5.2
Setting the date and time
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "DATE/TIME" with o u and confirm with E.
Date and time are displayed.
i
The cursor is automatically placed on the day's date.
5. Enter date and time using <0 – 9> and confirm
with E.
"
Date and time are set.
i
Return with <Stop>.
6.5.3
Set workshop data
i
The entry is limited to a maximum of 8 lines with 20
characters each.
i
Delete the space before the cursor with <MENU>.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "GARAGE" with o u and confirm with E.
5. Enter workshop data with <A – Z>,<0 – 9> and con-
firm with E.
i
Use o u to go to another line.
"
Workshop data are set.
i
Return with <Stop>.
|
S P00 D00 001
2019-02-21
6.6
is displayed.
i
Before the ACS 511 can be used, the internal refrig-
erant cylinder must be filled with liquid refrigerant.
Make exclusive use of R134a refrigerant.
i
The refrigerant can be obtained from your gas sup-
plier. It can be stored normally and transported in
vessels with connection fittings.
!
The internal refrigerant cylinder should only be
replaced if it is severely damaged. The internal
refrigerant cylinder must always be filled using an
external refrigerant cylinder.
is displayed.
!
During filling, the external refrigerant cylinder must
be firmly positioned and the operator must ensure
that the service hoses are safely routed to avoid the
danger of the external refrigerant cylinder falling
over.
i
The optimum quantity is approx. 4 - 8 kg.
!
Do not interrupt the automatic filling process prior
to automatic termination by the ACS 511.
!
ACS 511 automatically empties the service hoses
and internal lines after charge of the internal refrig-
erant cylinder using suction. This additional quantity
causes the actual filling capacity to deviate + 500 g –
700 g from the filled in refrigerant quantity.
Filling internal refrigerant cylinder
WARNING – Risk of frostbite from escap-
ing refrigerant
Refrigerant causes severe frostbite on the
skin.
¶
Check the service hoses for damage.
¶
Firmly connect the service quick-release
couplings to the service hoses.
¶
Wear safety goggles.
¶
Wear protective gloves.
Robert Bosch GmbH