en
54 | ACS 511 | Troubleshooting
10. Troubleshooting
i
Please contact customer service if any of the actions
suggested in this Section can not be implemented.
10.1
Service prompt
Messages
CHANGE OIL
REPLACE FILTER
10.2
Fault messages
Messages
HIGH PRESSURE
PROGRAM ERROR
FULL TANK
ZEROING OIL SCALES
HIGH RECOVERY TIME
A/C SYSTEM EMPTY
OUTOIL BOTTLE FULL CALIBRATE SCALE
OIL IN BOTTLE EMPTY FILL BOTTLE
A/C SYSTEM FULL
INCOMPLETE CHARGE
CHARGING OIL TIME HIGH
|
S P00 D00 001
2019-02-21
Actions
Change vacuum pump oil.
Combo filter replacement
Actions
There is excess pressure at the outlet of the compressor. Switch off the sta-
tion and wait approx. 30 minutes. If error persists, contact customer service.
If error persists, contact customer service.
The internal refrigerant cylinder has been filled to maximum filling level. Car-
ry out several refill procedures in order to reduce the internal refrigerant
quantity.
Error in scales setting. Perform "Tare scales". If error persists, contact cus-
tomer service.
The recovery time exceeds the set maximum duration. Check vehicle air con-
ditioner for leaks. If error persists, contact customer service.
There is no refrigerant in the vehicle air conditioning system.
The used oil bottle is full and must be emptied.
The fresh oil bottle is empty and must be refilled.
There is refrigerant in the air conditioning system.
The filling time exceeds the set maximum duration.
The bottle pressure equals the pressure in the vehicle air conditioning sys-
tem. Inform customer service.
The fresh oil filling time exceeds the set safety threshold.
There is no vacuum in the vehicle air-conditioning system. Create vacuum
first.
Robert Bosch GmbH