EN
3
COMMISSIONING
3.1
Preliminary operations
a
WARNING
– Should it be necessary to access the areas in the
bottom part of the appliance, make sure that the
system components and pipes are not hot (risk of
burning).
– Before replenishing the heating system, put on
protective gloves.
Before commissioning the appliance, check that:
– the type of gas is correct for the appliance
– the gas isolation valves for the heating system and the water
system are open
– the system pressure as shown on the pressure gauge when the
system is cold , is between 1 and 1.2 bar
– the pump impeller rotates freely.
3.2
Before commissioning
After having carried out the preliminary operations, perform the
following to start the boiler:
– set the main system switch to "ON"
ON
– the type of gas for which the boiler has been calibrated, "nG"
(methane) or "LG" (LPG,) will appear followed by the power.
After this the correct representation of the symbols will be
checked and finally "- -" will appear on the display
– press the button
s
once for at least 1 second to select "SUMMER
mode"
l
. The value of the delivery sensor detected at that
moment will appear on the display
– open one or more than one hot water tap. The boiler will work
at maximum power until the taps are closed.
– if there is a fault, the message "AL" will appear on the display
followed by the fault code (eg. "06" - no flame detected).
m
CAUTION
If the boiler has blocked, restore the start conditions by
pressing and holding the button
3 seconds. This operation can be carried out no more
than 6 times.
– close the taps opened previously and check that the appliance
shuts down
– press the button
value of the heating water temperature detected at that
moment will appear on the display
– adjust the air thermostat and check that the boiler starts and
operates correctly
– to check that the pressure in the network and the nozzles are
correct, the procedure described in section must be carried out
Fig. 31
"Chimney sweeper function".
3.3
Parameter setting and display
To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
same time until "tS" (installer) appears on the 2 digits of the
display which alternate with "0.1" (parameter number) and a
(set value)
"2"
o
(
R
) for more than
once to select "WINTER mode"
s
<
and
o
(approximately 5 seconds) at the
. The
n
21