Display of operating data and counters

Once the boiler is operating a qualified technician can view the
operating data "In" and the counters "CO" as follows:
– from the operating screen in the mode enabled at that moment
(WINTER
n
or SUMMER
– go into "INFO" by pressing the buttons
for more than 3 seconds until "In" appears alternating with
(information number) and "25" (eg. value)
"0.0"
From this point, the technician has 2 options:
– scroll through the list of "info" and "counters" by pressing the
button
>
. This way, scrolling will be in sequence
– display the "activated alarms" (no more than 10) by pressing
the button
<
. Once in this section, proceed with button
When all the values have been displayed, exit the menu by
pressing and holding down the buttons
for approximately 5 seconds until the initial screen is displayed.
TABLE OF INFORMATION DISPLAYED
Type
No. Description
In
0.0 SW version
In
0.1 External sensor
Delivery sensor 1
In
0.2
temperature
Delivery sensor 2
In
0.3
temperature
Domestic hot water
In
0.4
sensor temperature
In
0.5 AUX auxiliary sensor
Actual heating SET
In
0.6
temperature
In
0.7 Power level
In
0.8 Flow meter rate
Water pressure
In
0.9
transducer reading (if
resent)
24
l
)
and
>
<
at the same time
>
<
and
o
at the same time
Range
U/M
Step
- 9 .. 99
°C
- 9 .. 99
°C
- 9 .. 99
°C
- 9 .. 99
°C
- 9 .. 99
°C
Par. 13
... Par.
°C
14
0 .. 99
%
0 .. 99
l/min
0...99
bar
TABLE OF COUNTER DISPLAYED
Type
No.
Description
total no. of boiler
CO
0.0
operating hours
total no. of burner
CO
0.1
operating hours
total no. of burner
CO
0.2
ignitions
CO
0.3
total no. faults
total no. of
times installer
CO
0.4
parameters
"tS"accessed
total no. of times
CO
0.5
OEM parameters
accessed
time unitl next
CO
0.6
maintenance
intervention
total no. of
CO
0.7
calibrations
TABLE OF ACTIVATED ALARMS/FAULTS
Type
No.
Description
AL
00
Last activated alarm/fault
or
<
.
AL
01
Last but one activated alarm/fault
AL
02
Third from last activated alarm/fault
AL
03
Previous activated alarm/fault
AL
04
Previous activated alarm/fault
AL
05
Previous activated alarm/fault
AL
06
Previous activated alarm/fault
AL
07
Previous activated alarm/fault
AL
08
Previous activated alarm/fault
AL
09
Previous activated alarm/fault
3.6

Checks and adjustments

3.6.1

Chimney sweeper function

The chimney sweeper function is used by the qualified
1
maintenance technician to check the gas pressure at the
1
nozzles, detect the combustion parameters and to measure the
combustion efficiency required by legislation in force.
1
This function lasts 15 minutes and is activated by proceeding as
1
follows:
1
– if the panel (2) has not already been removed, remove the two
screws (1), pull the front panel (2) forwards and release it from
1
the top by lifting it
1
0.1
0.1
2
EN
Range
U/M
Step
0.1; from 0.0 to
0 .. 99
h x 1000
9.9; 1; from 10
to 99
0.1; from 0.0 to
0 .. 99
h x 1000
9.9; 1; from 10
to 99
0.1; from 0.0 to
0 .. 99
h x 1000
9.9; 1; from 10
to 99
0 .. 99
x 1
1
0 .. 99
x 1
1
0 .. 99
x 1
1
1 .. 199 months
1
1 .. 199
x 1
1
1
Fig. 33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8112106

Table des Matières