Description Of The Appliance; Characteristics; Check And Safety Devices; Identification - Sime Brava One 40 BF Manuel D'installation Et D'emploi

Masquer les pouces Voir aussi pour Brava One 40 BF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

  • FRANÇAIS, page 34
EN
1

DESCRIPTION OF THE APPLIANCE

1.1

Characteristics

Brava One 40 BF
are last generation low temperature wall mounted
boilers which Sime has produced for heating and domestic hot
water production. The main design choices made by Sime for the
boilers are:
Brava One 40 BF
– the atmospheric burner combined with a copper heat
exchanger for heating and a rapid heat exchanger for DHW
– the sealed combustion chamber which can be classified "Type
C" or "Type B" in relation to the room where the boiler is
installed, depending on the smoke outlet configuration adopted
during installation
– the command and control microprocessor electronic board not
only allows a better management of the heating system and
the system for domestic hot water production but it can also
be connected to air thermostats or a remote control (with an
Open Therm protocol), an auxiliary sensor for the connection
of any possible solar kits or to an external sensor. If this is the
case, the boiler temperature varies on the basis of the external
temperature according to the selected optimal climatic curve
allowing for significant energy and economic savings.
Other special features of the Brava One 40 BF boilers are:
– the anti-freeze function which activates automatically if the
temperature of the water inside the boiler falls below the
threshold of the value set at parameter "tS 1.0" and , if there is
an external sensor, if the external temperature falls below the
threshold of the value set at parameter "tS 1.1".
– the anti-blocking function of the pump and diverter valve, this
activates automatically every 24 hours if no request for heat
has been made
– the chimney sweep function lasts 15 minutes and makes the
job of the qualified technician easier when measuring the
parameters and combustion efficiency and when checking gas
pressure at the nozzles
– screen display of the operating and self-diagnostic parameters
with error code display when the fault occurs. This makes
repair interventions easier and allows appliance operation to
be restored correctly.
1.2

Check and safety devices

The Brava One 40 BF boilers are equipped with the following check
and safety devices:
– thermal safety sensor 100°C
– 3 bar relief valve
– heating water pressure switch
– delivery sensor
– DHW sensor.
d
IT IS FORBIDDEN
to commission the appliance with safety devices which
do not work or which have been tampered with.
a
WARNING
Safety device may only be replaced by professional
qualified personnel using Sime original spare parts.
1.3

Identification

The Brava One 40 BF boilers can be identified by means of:
this is located on the outside of the packaging
1
Packaging label:
and provides a code, the serial number of the boiler and the
bar code
2
Technical Data Plate:
this is located inside the front panel of
the boiler and provides the technical specification, appliance
performance and any other information required by law.
1
2
m
CAUTION
Tampering with, removing or failing to display the
identification plate or carrying out any other operation
which does not allow safe identification of the product
or which may hinder installation and maintenance
operations.
1
2
Fig. 1
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8112106

Table des Matières