OPERATION
Switching on/off the automatic pan detection
If, after the hob has been turned on, a pan is placed in an inactive
cooking zone, the operating controls light up and this can be used
immediately (without operating the on/off switch).
If the cooking zone is not activated within 10 seconds, the light will go
out. It can be re-activated by removing the pan and then replacing it or
by using the on/off switch.
This function is active by default, but can also be switched off. This is
done by switching the hob off and operating the 'wok' button (19) and
'on/off button' (6) on the left-hand control panel for 5 seconds. 'APd
OFF' will appear on the display. By repeating this process, the function
can be reactivated and the 'APd On' will appear on the display.