INSTALLATION INSTRUCTIONS
Safety instructions for the installation
Clearance
*
HI1345G: min. 40 cm
• The connection must comply with national and local regulations.
• The appliance must always be earthed.
• This appliance may only be connected by a competent electrical
installer.
• Always connect the appliance to an earthed socket.
• The connection cable must hang freely and is not to be fed through
a drawer.
• If you want to make a fixed connection, make sure that a multi-
polar switch with a contact separation of at least 3 mm is fitted in
the supply line.
• The worktop the hob is built into must be flat.
• The walls and the worktop surrounding the appliance must be heat
resistant up to at least 85 °C. Even though the appliance itself does
not get hot, the heat of the hot pan could discolour or deform the
wall.
• Damage caused by incorrect connection, installation or use, will not
be covered by the guarantee.
Sufficient all-round clearance is essential to the safe use of the hob.
Check that there is enough clearance.
cabinet
cabinet
cooker hood
cooker hood
hob
hob
side wall
side wall
EN 23