English
7.7
Tea delivery
By pressing the corresponding button (T6 or T7), the
corresponding dispensing solenoid valves are activated
until the previously programmed product quantity (time
control) is reached.
The LIGHT corresponding to the button of the selected
TEA dose will be steady on during the whole hot water
dispensing phase while the other one will be off.
The simultaneous delivery of tea or coffee is possible.
It is possible to stop dispensing before the programmed
product quantity is reached by pressing the dose button
used for dispensing the product again.
T6 and T7 buttons can not
be used simultaneously.
7.8
Powersteam steam wand
dispensing
By
pressing
the
corresponding
corresponding dispensing solenoid valve is activated until
the previously programmed temperature is reached.
The LIGHT corresponding to the powersteam button will
be steady on during the whole steam dispensing phase.
It is possible to dispense steam, Tea and coffee
simultaneously.
68
It is possible to stop dispensing before the programmed
temperature is reached by pressing the powersteam
button again.
When the programmed temperature is reached it is
possible to continue to dispense steam by keeping the
steam button pressed.
If temperature is not reached within a time-out of 120
seconds, the steam dispensing is stopped automatically.
7.9
It is possible to activate or deactivate some special
functions PRE_INFUSION, MIXED TEA and WASHING
described below:
Pre-infusion
Our software permits measure configuration so that the
relative delivery of the COFFEE measures through
volumetric control is preceded by pre-infusion.
Delivery of the coffee measure after time 1 (ON) is
suspended for a time 2 (OFF) and is then resumed for the
completion of selection.
On pressing one of the volumetric control measure keys,
the normal delivery cycle is preceded by a short timed
water jet in order to dampen the coffee pellets before
actual delivery stage.
This function ensures the optimum use of the coffee
pellets.
button
T8,
the
Mixed tea (hot water)
On the engagement of this function the water delivered is
mixed with cold water on entry in the boiler thereby
ensuring constant delivery at a temperature of about 96°C.
If this function is not engaged water is delivered at a
temperature of about 100°C and is highly vaporized.
Special functions