5.2
Electrical connection
Before
proceeding
electrical connection it is
necessary to check to
ensure that the voltage
rating corresponds with
that indicated on the CE
plate
and
connection plate on the
power supply cable. Check
to ensure that the electrical
supply line is able to
support the machine load
(see
chap.
features").
Connect to an earthing socket which complies with
current legislation.
Check that the power
supply cable is efficient and
that
it
complies
national
and
safety standards.
The user must undertake to
power
protecting the power line
using a suitable safety switch
(cut-out) that complies with
the legislation in force in the
actual country itself.
with
on
the
"technical
with
European
the
machine
Connect the power cable (E) to the electric line using a plug, or
in the case of fixed installation, using a multi-polar switch (D) for
mains separation, with a contact distance of at least 3 mm.
For voltage change refer to the diagram shown on the general
mains switch box.
The yellow-green coloured
cable MUST be connected
to the room's earthing
system.
Depending on the current
regulations of the Country
where the machine operates,
the cable connecting the
electric line has to be pre-set
or equipped with an all-pole
switch (with a minimum
contact opening of 3 mm),
(or with a plug in accordance
with the same regulations).
It is recommended to install a
residual current device (RCD)
with a rated residual current
not exceeding 30 mA.