Troubleshooting; Safety Notices; Troubleshooting Table - CASO DESIGN VC 250 Mode D'emploi

Masquer les pouces Voir aussi pour VC 250:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Attention
► Bags used to store raw meats, fish or greasy foods should never be reused due to risk of
contamination.
Sealing profile (which presses the bag against the sealing bar)
Remove the sealing profile and clean it in warm soapy water.
Please note
► The sealing profile should be cleaned thoroughly before installing it again.
► Be careful during re-installation, so that nothing will be damaged and sealing profile is
placed well so that the device can work properly.

7 Troubleshooting

This chapter provides you with important notices with regard to operating the device. Observe
the following notices to avoid dangers and damages:

7.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer may carry out any
repairs on electrical equipment.
► Improperly performed repairs may result in personal injury or damage to the device.

7.2 Troubleshooting table

Error
Vacuum unit is not
functioning
The first weld on the
cut off piece of the roll
is not being carried
out.
A complete vacuum is
not being created in
the bag.
Possible Cause
Power plug is not plugged in
Defective power cable or plug Contact Customer Service
Defective electrical socket
Roll is not positioned
correctly
The open end of the bag is
not completely inside the
vacuum chamber
Solution
Plug in mains plug!
Select another electrical socket
Follow the steps in the chapter
"making a bag using the bag roll"
Position the bag correctly
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

11522

Table des Matières