Cleaning; Troubleshooting; Safety Notices; Troubleshooting Table - CASO DESIGN VRH 490 advanced Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46

18.2 Cleaning

Outside of the unit
Wipe with a damp cloth or sponge and mild dish soap.
Inside of the unit
Wipe away any food or liquids with a paper towel.
Remove the drip tray and wash it with warm water and a mild dishwashing soap. Dry it
carefully and replace it.
Cleaning bags for reuse
Wash the bags in warm water with a mild dishwashing soap, then rinse them well and
allow them to dry completely before reusing
Attention
► Bags used to store raw meats, fish or greasy foods should never be reused due to risk
of contamination.
Sealing profile (which presses the bag against the sealing bar)
Remove the sealing profile and clean it in warm soapy water.
► The sealing profile should be cleaned thoroughly before installing it again.
► Be careful during re-installation, so that nothing will be damaged and sealing profile is
placed well so that the device can work properly.

19 Troubleshooting

The following table may help you narrow down and address minor malfunctions:

19.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer may carry out
any repairs on electrical equipment.
► Improperly performed repairs may result in personal injury or damage to the device.

19.2 Troubleshooting table

Error
Vacuum unit is not
functioning
The first weld on the
cut off piece of the roll
is not being carried
out.
Please note
Possible cause
Power plug is not plugged in
Defective power cable or plug Contact Customer Service
Defective electrical socket
Roll is not positioned
correctly
.
Rectification
Plug in mains plug!
Select another electrical socket
Follow the steps in the chapter
"making a bag using the bag roll"
42

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1525

Table des Matières