Cleaning bags for reuse
Wash the bags in warm water with a mild dishwashing soap, then rinse them well and
allow them to dry completely before reusing
ATTENTION
► Bags used to store raw meats, fish or greasy foods should never be reused due to risk
of contamination.

19 Troubleshooting

The following table may help you narrow down and address minor malfunctions:

19.1 Safety notices

ATTENTION
► Only qualified electricians, who have been trained by the manufacturer may carry out
any repairs on electrical equipment.
► Improperly performed repairs may result in personal injury or damage to the device.

19.2 Troubleshooting table

Fault
Device does not turn
on
A complete vacuum
is not being created
in the bag.
The bag is not being
sealed correctly
The bag does not
hold the vacuum
after it has been
sealed
Possible Cause
Power plug is not plugged in.
Defective power cord
Defect socket outlet
The open end of the bag is not
completely inside the vacuum
chamber
The bag is defect
There is residue on the welding
and the seal
The sealing bar is overheating
so that the bag melts
Defect sealing bar.
The bag is defective
There are leaks along the
welding seam as a result of
creases, crumbs, grease or
liquids.
.
Plug in the power plug.
Send device to Customer Service
Select other outlet
Position the bag correctly
Select another bag
Clean the welding / seals and
retry once they are dry
Open the cover on the unit and
let it cool down for a few minutes.
Sealing bar needs to be replaced.
Select another bag; wrap paper
around any sharp edges within
the bag.
Open the bag again and clean
the upper internal part of the bag.
Remove any foreign matter that
might be on the welding bar
before sealing.
To Rectify