5.  SETTINGS VIA CONTROL PANEL
5.1.  ADJUSTING THE WATER TEMPERATURE
The unit starts from the set temperature
Setting the maximum water temperature for
cooling
By setting the temperature lower, the unit will
start later. If the water temperature is set higher,
the unit will start faster .
1. Put the device in the cooling mode
2. Hold down the [Mode] and [+] simultaneously
until the last 4 LEDs start flashing .
3. Briefly press the [-] or [+] button to adjust the set temperature .
4. After 30 seconds, the new settings are automatically saved and the device returns to the selected
mode. .
24
28
/
.
MODE
12 ̊ C
MODE
MODE
14 ̊ C
MODE
MODE
16 ̊ C
MODE
MODE
18 ̊ C
MODE
MODE
20 ̊ C
MODE
MODE
22 ̊ C
MODE
MODE
24 ̊ C
MODE
MODE
26 ̊ C
MODE
MODE
set minimum water temperature heating
By setting the temperature higher, the unit will
start later. If the water temperature is set lower,
the unit will start faster .
When using a heat pump, it may be necessary
to set the water temperature at a lower setting .
1. Put the device in heating mode
2. Hold down the [Mode] and [+] simultaneously
until the last 4 LEDs start flashing .
15 sec
24 ̊ C
26 ̊ C
28 ̊ C
30 ̊ C
32 ̊ C
34 ̊ C
36 ̊ C
38 ̊ C
24
/
28
factory default water temperature