To be sure that starting relay will function and
that overload will not "nuisance trip", install
control box vertically with top side up.
Wire control box as shown in Figures 1A and
1B. A 3-wire pump will not operate without
control box. Operation without control box will
burn out 3 wire motor.
Installation must include circuit and component
protection which meet local code and United
States National Electrical Code requirements.
If main overload trips, look for:
1. Shorted Capacitor
2. Voltage Problems
3. Overloaded or locked pump.
NOTICE: Match motor to control box as shown
below. Motor and control box model numbers
may include additional suffix numbers to the
right of the numbers shown here. These addi-
tional numbers are not important for control box
selection.
TABLE IV: Control Box Selection
HP
Voltage
Motor No.
1/2
115
214504
214305
1/2
230
214505
214307
3/4
230
214507
214308
1
230
214508
1-1/2
230
214300
2
230
224301
3
230
234 316 52
115V or
Ground
230V Line
FIGURE 1A - 3-wire, 1/2 thru 1 HP quick disconnect
box. Follow color coding when connecting control box
(Yellow to Y, Red to R, Black to B).
Control Box No.
28010449
To Line
28010549
28010749
28010849
28230081
28230181
28230183
Fused
28230281
Disconnect
28230283
Switch
FIGURE 1B - Single phase, 2-wire connections. 2-wire
pumps have two power supply wire (Red/Black) and
one ground wire (Green). Control box is not required.
See Figure 1B for correct hook-up information for 230
volt 2-wire motors only.
4
Fused
Sub.
disconnect
Motor
switch
Control
L1L2R Y B
L1 M1
L2
M2
Pressure
switch
Red
Yellow
Black
Ground
Well
casing
699 0993
Ground
L1
M1
L2
M2
Pressure
Switch
Red
Black
Ground
(Green)
Well
Casing
336 1093