Bosch 3.011 Instructions D'emploi page 40

Appareil d'analyse des émissions
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5.2 Software versions
By pressing ENT, you can display three pieces of information
containing a number and date, one after the other:
VSM Power-supply control module, with national code
MTM Motor Test Module (contained in the VSM)
RTM Opacimeter
5.3 Language
In the "LANGUAGE" submenu, you can select the language
you want to work with using the z
confirm your selection by pressing ENT. This setting is stored
permanently, i.e. it is not lost when the Measuring Instrument
is switched off.
5.4 Date and time
In the "DATE/TIME" submenu, you can choose between "DIS-
PLAY" and "SET". In the first case, you cannot make any
changes; in the latter, you are switched to Edit mode (see section
2.3.2, "Input or Edit mode") and you can re-enter or change the
date and/or time. The field that can be changed flashes; pressing
ENT moves you to the next field. Pressing ESC either exits the
menu or displays the old setting if changes have been made.
5.5 Report heading
The "REPORT HEADING" submenu contains 7 lines in which
enter the address of the test station.
The details of the test station are then printed out automatically on
the report printouts.
40
z
z
z and v
z
v cursor keys and then
v
v
v
5.6 Printer
In the "PRINTER" submenu, you can set the printer type and the
form of the report printout.
PRINTER
INTERNAL
The test report is printed out either on the internal tape printer or
on the external PDR 202 printer.
PRINT DEALER?
The 7 x 24 characters described in section 5.5, "Report header",
which contain the test station (dealer's) address can either be
printed or not.
PRINT CUSTOMER?
The 6 x 24 characters of customer identification (usually the
name and address) can either be printed in the test report or
not. If you select YES, you can enter this information during the
test procedure, but at no other time.
PRINT VEHICLE?
The vehicle data (registration number, manufacturer, model
etc.) can either be printed in the test report or not. If you select
YES, you can enter this information during the test procedure,
but at no other time.
5.7 Units
In the "UNITS" submenu, you can choose between two units of
measurement for the opacity values:
K value in:
Opacity value in:
This setting only affects what is displayed in the "TEST
FUNCTION OPACITY" menu.
5.8 Oil temperature
You use the "OIL TEMPERATURE" submenu to set whether the
oil temperature is to be measured or not during the course of a
test.
DO NOT MEASURE
MEASURE
or
EXTERNAL
YES
or
NO
YES
or
NO
YES
or
NO
m
-1
or
%
In the test procedure, the user only
sees the instruction
WAIT UNTIL ENGINE IS WARM.
The oil temperature is always
measured

Publicité

Table des Matières
loading

Table des Matières