Disposal; Spare Parts; Designation Of Parts - Calpeda NM Instructions Originales Pour L'utilisation

Pompes centrifuges à un étage monobloc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
When the pump remains inactive it must be emptied
completely if there is a risk of freezing
GB
Fig. 4 Draining.
Before restarting the unit, check that the shaft is not
jammed and fill the pump casing completely with liquid.
8.2 Maintenance Pumps with packing seal
First loosen the gland slightly so that the seal is decom-
pressed. Then adjust the gland, leaving a regular leaka-
ge-drip, which indicates proper lubrification.
The packed gland must be replaced when its sealing
properties have considerably decreased. A compres-
sed, hardened and dry packing causes the shaft to
wear.
8.3 Bearings lubrication
Up to frame size 160 the motors have prelubricated
bearings and they do not require any relubrication.
From frame size 180 the motors have grease nipples. A
relubrication at regular intervals (about 5000 h) is
recommended only in heavy working conditions, with
high ambient temperatures. An excess of grease is
harmful. Use lithium base grease for high temperatures.
8.4 Dismantling the system
Close the suction and delivery gate valves and drain
the pump casing before dismantling the pump.
8.5. Dismantling the pump
OFF
Close the suction and delivery gate valves and drain the
pump casing before dismantling the pump.
For dismantling and reassembly see construction in the
cross section drawing.
The motor and all internal parts can be dismantled
without removing the pump casing and pipes.
By removing the nuts (14.28) the motor can be taken
out complete with the impeller.

9. DISPOSAL

OFF
The final disposal of the device must be done by spe-
Page 14 / 88
cialized company.
.
Fig. 4
Make sure the specialized company follows the
classification of the material parts for the separation.
Observe the local regulations and dispose the device
accordingly with the international rules for environ-
ment protection.

10 SPARE PARTS

10.1 Spare-parts request
When ordering spare parts, please quote their desi-
gnation, position number in the cross section drawing
and rated data from the pump name plate.
The spare parts request shall be sent to CALPEDA
S.p.A. by phone, fax, e-mail.
4.93.142

11 DESIGNATION OF PARTS

Nr.
Designation
14.00 Pump casing
14.04 Plug (filling)
14.12 Plug (draining)
14.20 O-ring
14.24 Screw
14.28 Nut
28.00 Impeller
28.04 Impeller nut
28.12 Circlip
28.20 Impeller key
32.00 Lantern bracket
32.30 Guard
32.32 Screw
32.33 Caged Nut
34.00 Casing cover
36.00 Mechanical seal
36.50 Shoulder ring
46.00 Deflector
64.00 Pump shaft
66.00 Ball bearing, coupling side
66.18 Circlip
70.18 Screw
70.19 Nut
73.00 Pump-side bearing
76.00 Motor casing with winding
76.04 Cable gland
76.16 Support
76.20 Pin
76.54 Terminal box, set
78.00 Shaft with rotor packet
81.00 Fan-side bearing
82.00 Motor end shield, fan side
82.04 Compensating spring
88.00 Motor fan
90.00 Fan cover
90.04 Screw
92.00 Tie-bolt
94.00 Capacitor
94.02 Capacitor gland
98.00 Terminal box cover
98.04 Screw
98.08 Gasket
99.00 Motor, complete
Changes reserved.
NM, NMS, NM4, NMS4 Rev. 24 - Operating Instructions

Publicité

Table des Matières
loading

Table des Matières