8.1. Routine maintenance
OFF
Before
disconnect the power supply and make sure
EN
that the device could not accidentally operate.
For good measure, as in the case of temporary
operation with dirty liquids, run the pump
briely with clean water to remove deposits.
When the pump remains inactive it must be
emptied completely if there is a risk of freezing
(par. 12.3 ig. 4).
To empty completely the NMD and C 16 pumps it is also
necessary to take out the delivery casing (20.00/14.00)
by removing the screws (20.12/14.24).
Before restarting the unit, check that the shaft is not
jammed and ill the pump casing completely with liquid.
8.2. Dismantling the system
Close the suction and delivery gate valves and drain
the pump casing before dismantling the pump.
8.3. Dismantling the pump
OFF
Close the suction and delivery gate valves and drain
the pump casing before dismantling the pump.
For dismantling and re-assembly see construction in
the cross section drawing.
With the NM, C, pumps the motor can be taken out, by
remowing the screws (14.24), complete with impeller
without removing the pump casing and the pipes.
With NMD pumps it is also necessary to take out the
pump casing (suction casing 16.00 or delivery casing
20.00) by removing the screws (20.12).
8.4. Pumps with IP 55 protection (Special con-
struction)
OFF
To always assure IP 55 degree of protection, it is
necessary to check the following points:
- Before starting the motors, carefully control the
position of the gasket between terminal box and
its cover. For cable of small size, use a protective
covering between cable and cable gland.
- When disassembling the end shields of the motors,
restore the existing joint using the sealing glue
LOCTITE type 510 or other equivalent sealing
system, if any, and check the perfect assembly of the
sealing ring on the shaft.
9. DISPOSAL
OFF
The inal disposal of the device must be done by
specialized company.
Make sure the specialized company follows the
classiication of the material parts for the separation.
Observe the local regulations and dispose the device
accordingly with the international rules for environment
protection.
Page 12 / 64
every
maintenance
European Directive
2012/19/EU (WEEE)
www.calpeda.su
10. SPARE PARTS
10.1.
When ordering spare parts, please quote their
designation, position number in the cross section
operations
drawing and rated data from the pump name plate
(type, date and serial number).
The spare parts request shall be sent to CALPEDA
S.p.A. by phone, fax, e-mail.
11. DESIGNATION OF PARTS
Nr.
14.00
14.04
14.12
14.20
14.24
16.00
16.04
16.12
16.20
18.00
20.00
20.04
20.12
28.00
28.04
28.12
28.20
30.00
32.00
32.30
32.32
32.33
36.00
36.50
46.00
70.00
70.18
70.19
70.20
73.00
76.00
76.04
76.16
76.20
76.54
78.00
81.00
82.00
82.04
88.00
90.00
90.04
92.00
94.00
94.02
98.00
98.04
98.08
99.00
Changes reserved.
Spare-parts request
Designation
Pump casing
Plug (illing)
Plug (draining)
O-ring
Screw
Suction casing
Plug with washer
Air release plug with washer
Casing gasket
Interstage plate
Delivery casing
Plug with washer
Screw
Impeller
Impeller nut
Circlip
Impeller key
Impeller
Lantern bracket
Guard
Screw
Caged Nut
Mechanical seal
Shoulder ring
Delector
Lantern bracket
Screw
Nut
Screw
Pump-side bearing
Motor casing with winding
Cable gland
Support
Pin
Terminal box, set
Shaft with rotor packet
Fan-side bearing
Motor end shield, fan side
Compensating spring
Motor fan
Fan cover
Screw
Tie-bolt
Capacitor
Capacitor gland
Terminal box cover
Screw
Gasket
Motor, complete
NM-NMD Rev24 - Operating Instructions