In order to clean the surface opposite the blade and the ring, it is necessary
to remove the slicing machine blade. Caution! This procedure is only
recommended if in possession of the plexiglass blade extractor. The
procedure for extracting the blade is as follows (see Fig. 18):
1. Remove the product holder tray
(see paragraph 6.2.1)
2. remove the blade guard (Fig. 16)
3. remove the sharpening device (a)
and, using the graduated dial, set
the ribbed thickness gauge tray
(g) to "0";
4. rest the extractor (b) on the
blade, so that the discharge (h)
coincides with the position of the
ring (c);
5. tighten the two dials (e) without
overtightening them;
6. unscrew the screws (f) securing
the
blade,
gloves and remove the blade
securely by gripping the two
knobs;
7. after cleaning, replace the blade
by
performing
reverse over
6.2.3 CLEANING THE SHARPENER
The sharpener body must be cleaned using a cloth with mild detergent, while
the wheels must be cleaned using a toothbrush with metal bristles.
6.2.4 CLEANING THE SLICE DEFLECTOR
To remove the slice deflector, simply
unscrew the two screws (a) that
keep it locked in place and pull up the
tab (C). Now clean the slice deflector
with water and mild detergent.
All manuals and user guides at all-guides.com
using
protective
the
steps
in
Figure 22 - Positioning the blade
extraction jig
Figure 23 - View of the slice
deflector
29