Maintenanceandtroubleshooting
10.
mAinTenAnce And
TRoubleshooTinG
10.1.
safety instructions
dangEr
danger due to high pressure in the installation.
•
Shut down the pneumatic power source and depressurise the
pipes before carrying out work on the device.
Risk of injury due to electrical discharge.
•
Before starting work, switch off the power supply and secure it
from restarting.
•
Observe all applicable accident protection and safety regula-
tions for electrical equipment.
Warning
Risk of injury due to non-conforming maintenance.
•
Maintenance must only be carried out by qualified and skilled
staff with the appropriate tools.
•
Guarantee a set or controlled restarting of the process, after a
power supply interruption.
10.2.
cleaning of the transmitter
The external surface of the electrical position feedback can be
cleaned with a cloth dampened with water or a product compatible
with the materials from which it is made.