Installationandwiring
8.2.1.
Wiring a mechanical contact version
noTE
on a mechanical contact version, the used contact is not
voltage free.
Do not connect the unused contact in order to obviate any danger
of malfunction.
Green light (open
valve detection)
Orange light (volt-
age present)
1062
Fig. 7
Wiring of the contact when normally open (NO) on a
mechanical contact version, valve open detection
Use a power supply that matches the data shown on the label of the 1062
1)
All manuals and user guides at all-guides.com
Type 1062
Fuse suitable for
the max. load
-
+
NC
NO
+
-
Power supply
Load
+ -
8 A max.
Green light (open
valve detection)
Orange light (volt-
age present)
Fig. 8
Wiring of the contact when normally closed (NC) on a
mechanical contact version, valve open detection
1)
1)
Use a power supply that matches the data shown on the label of the 1062
Fuse suitable for
the max. load
-
1062
+
NC
NO
Power supply
+ -
8 A max.
Load