Annexe C
Calendrier de maintenance préventive
Commissioning Activities
Door Mounted Air Filters
Air-Cooling
Main Cooling Fan Motor
System
Redundant Cooling Fan Motor (if supplied)
Small Aux. Cooling Fans "Caravel"
Mesh Filters
De-ionizing Filter Cartridge
Liquid-Cooling
All Fittings/Connections/Hose Clamps
System
Redundant Cooling Pump Motors/Pumps
Redundant Cooling Pump Motor Seals
Thermostatic Valve Element
Power Devices (SGCTs/SCRs)
Snubber Resistors/Sharing Resistors/HECS
Rectifier Snubber Capacitors
Power Switching
Components
Inverter Snubber Capacitors
Integrated Gate Driver Power Supply
Self-Powered SGCT Power Supply (SPS)
Isolation Transformer/Line Reactor
Integral
Magnetics/Power
DC Link/Common Mode Choke
Filters
Line/Motor Filter Capacitors
AC/DC and DC/DC Power Supplies
Control Boards
Control Cabinet
Components
Batteries (DCBs and CIB)
Battery Module (UPS)
Low Voltage Terminal Connections/
Plug-in Connections
Medium Voltage Connections
Connections
Heatsink Bolted Connections
Medium Voltage Connections (Rectifier)
Medium Voltage Connections (Inverter)
Firmware
Enhancements
Hardware
Parameters
Operational
Variables
Conditions
Application Concerns
Spare Parts
Inventory/Needs
Only applies to air-cooled VFDs (i.e. 'A' Frame and 'B' Frame)
If filter supplied is not a washable type, replace filter. If filter supplied is a washable type, wash or replace (depending on state of filter).
Only applies to liquid-cooled VFDs (i.e. 'C' Frame)
A 4 year replacement interval applied to all 6-pulse and 18-pulse rectifier versions with previously available rectifier snubber capacitors. Snubber capacitors now
available extend the replacement period of "B" and "C" frames to 10 years (replacement period for "A" Frames remain at 4 years) – contact Cambridge for details and
to purchase extended life snubber capacitors. Active Front End rectifiers have a 10 year rectifier snubber capacitor replacement interval.
Replace UPS battery module yearly for 50°C rated VFDs.
When rectifier snubber capacitors are replaced, the MV connections for rectifier need to be inspected.
When inverter snubber capacitors are replaced, the MV connections for inverter need to be inspected.
These components may be serviced while the VFD is running.
174
Interval Period (in years)
11
C/R
I
I
I
C
R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Publication Rockwell Automation 7000A-UM200C-FR-P – Juin 2014
12
13
14
15
C/R
C/R
C/R
C/R
I
I
RFB/R
I
I
I
RFB/R
I
I
I
I
R
C
C
C
C
R
R
R
R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
I
R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
RFB/R
I
I
I
RFB/R
I
I
I
M
I
I
I
M
I
I
I
M
I
I
I
RFB/R
I
I
I
I
R
I
I
R
I
I
I
R
I
I
I
I
I
I
I
I
I
I
I
I
I
Rv
Rv
Rv
Rv
Rv
I
I
Rv
Rv
I
I
Rv
Rv
I
I
Rv
Rv
i
I
Rv
16
17
18
19
C/R
C/R
C/R
C/R
I
I
I
I
I
I
I
I
I
I
I
I
C
C
C
C
R
R
R
R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
R
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Rv
Rv
I
I
Rv
I
I
I
Rv
I
I
I
Rv
I
I
I
Rv
I
20
C/R
I
I
R
C
R
I
I
R
I
I
I
Rv/R
R
RFB/R
RFB/R
M
M
M
RFB/R
I
I
R
I
I
I
I
I
I
I
I
I

Publicité

Table des Matières
loading

Table des Matières