2.4
CORRECT CONNECTION TO CHIMNEY
In picture 5 you can see some examples for
a correct connection of a wood fired cooker.
For a safe connection to the flue, we suggest
to use a double isolation of the wall. The
connection between the double isolation
and the flue must be well sealed. It is very
important that the connection between the
wood fired cooker and the flue is as short
NO
Picture 5 - Examples of correct and uncorrect chimney hood connection
Model
ø
entrance
ø
flue H < 4m
ø
flue 4 m < H < 6m
ø
flue H > 6m
Necessary depression
Table 2 - Indications for the dimension of the chimney according to its
height
2.5
PREDISPOSITION OF THE SMOKE OUTLET
The cooker is endowed with a predisposi-
tion for the smoke outlet both upper and
rear. The cooker usually has the two outlets
covered. To make the connection to the
as possible. The connection must be always
placed horizontally or inclined upwards,
never downwards. Bended or winding parts
of pipe must be avoided. The connection be-
tween the cooker and the flue must be well
fixed and sealed. The connections must not
cross inflammable or sensible to high tem-
peratures furnitures.
NO
NO
S
130 mm
Draught not guaranteed
160 mm
150 mm
12 Pa
chimney hood it is necessary to remove the
cap of the outlet to be used then insert the
conjunction device, see picture 7.
51
YES
H
Picture 6 - H dimension for the sizing of
the flue