Section 2
Water Supply and Drains
POTABLE WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
POTABLE WATER INLET LINES
Follow these guidelines to install water inlet lines:
•
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
•
If water pressure exceeds the maximum (80 psig/
551.5 kPA) recommended pressure, obtain a water
pressure regulator from your Manitowoc distributor.
•
Install a water shut-off valve and union for both the
ice making and condenser water lines.
•
Insulate water inlet lines to prevent condensation.
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Water Temperature
45°F (6°C) Min.
Ice Making
Water Inlet
90°F (32.2°C) Max.
Bin Drain
VENT TUBE
8" (20 cm)
LONG
Typical Water Supply Drain Installation
Part Number 000007651 05/10
Water Pressure
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
---
BIN DRAIN
WATER
SHUT-OFF
VALVE
ICE MAKING
WATER INLET
TUBING 3/8" MIN.
I.D. (.95 cm)
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:
•
Drain lines must have a 1.5 inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
•
The floor drain must be large enough to
accommodate drainage from all drains.
•
Run separate bin and water-cooled condenser drain
lines. Insulate them to prevent condensation.
•
Vent the bin and ice machine drain to the
atmosphere. The ice machine drain requires an 18"
vent. Do not vent the condenser drain on water-
cooled models.
•
Drains must have a union or other suitable means to
allow in place disconnection from the ice machine
when servicing is required.
Ice Machine Fitting
3/8" Female
Pipe Thread
3/4" Female
---
Pipe Thread
Plumbing Must Conform To all Local and National
Codes
If you are installing a Manitowoc water filter system,
refer to the Installation Instructions supplied with the
filter system for ice making water inlet connections.
Installation Instructions
Tubing Size Up to Ice
Machine Fitting
3/8" (9.5 mm) minimum
inside diameter
3/4" (19.1 mm) minimum
inside diameter
! Caution