NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
OPERATING PRECAUTIONS
Thisisapropane,direct-fired,forcedairheater.It'sintended
useisprimarilytemporaryheatingofbuildingsunder
construction,alterationorrepair.
Propaneisheavierthanair.Ifpropaneleaksfroma
connectionorfitting,itsinkstothefloor,collectingthere
withthesurroundingair,formingapotentiallyexplosive
mixture.Obviously,propaneleaksshouldbeavoided,soset
upthepropanesupplywithutmostcare.ReadenclosedOdor
FadeandPropaneSheetforadditionalinformationabout
detectingpropaneleaks.Leakchecknewconnectionsor
reconnectionswithasoapandwatersolutionandfollowall
connectioninstructionsherein.Also,askyourpropanedealer
foradviceonthepropaneapplicationandsupplyinstallation
andaskhimtocheckitifthereareanyquestions.
Thisheaterwasdesignedandcertifiedforuseasa
constructionheaterinaccordancewithANSIStandardZ83.7/
CGA2.14.Checkwithyourlocalfiresafetyauthorityifyou
haveanyquestionsaboutyourapplications.Otherstandards
governtheuseoffuelgasesandheatproducingproducts
inspecificapplications.Yourlocalauthoritycanadviseyou
aboutthese.
Direct-Firedmeansthatallofthecombustionproductsenter
theheatedspace.Eventhoughthisheateroperatesvery
closeto100percentcombustionefficiency,itstillproduces
smallamountsofcarbonmonoxide.Carbonmonoxide(called
CO)istoxic.Wecantoleratesmallamountsbutnotalot.
COcanbuildupinaheatedspaceandfailuretoprovide
adequateventilationcouldresultindeath.
The symptoms of inadequate ventilation are:
•headache
•dizziness
•burningeyesandnose
•nausea
•drymouthorsorethroat
So,besuretofollowadviceaboutventilationinthese
operatinginstructions.
ForcedAirmeansthatablowerorfanpushestheairthrough
theheater.Propercombustiondependsuponthisairflow;
therefore,theheatermustnotberevised,modifiedor
operatedwithpartsremovedormissing.Likewise,safety
systemsmustnotbecircumventedormodifiedinorderto
operatetheheater.
When the heater is to be operated in the presence
of other people the user is responsible for properly
acquainting those present with the safety precautions
and instructions, and of the hazards involved.
VENTILATION:Minimumopeningsrequired
Figure 1:
Heater
Forcedair(MH170QFAVT)
Opening
Opening
nearfloor
nearceiling
3ft
3ft
2
2
Force-Air Propane Construction Heater
SAFETY PRECAUTIONS
1.
Checktheheaterthoroughlyfordamage.DONOToperatea
damagedheater.
2. DONOTmodifytheheateroroperateaheaterwhichhasbeen
modifiedfromitsoriginalcondition.
3. Useonlypropanegas.
4. UseonlyVAPORWITHDRAWALpropanesupply.Ifthereisany
questionaboutvaporwithdrawal,askyourpropanedealer.
5. Mountthepropanecylindersvertically(shutoffvalveup).
Securethemfromfallingorbeingknockedoverandprotect
themfromdamage.
6. Locatepropanecontainersatleast(USA)7ft.(2.13m),
(Canada)10ft.(3m)fromtheheateranddo notdirect
exhausttowardcontainers.
7.
IMPORTANTUseonlythehoseandregulatorassembly
providedwiththeheater.Matchthecolorstripeonthehang
tagattachedtothehoseassemblywiththecoloronthelabel
locatednearthepropaneinletfittingontheheater.Inspect
hoseassemblybeforeeachuseoftheheater.Ifthereis
excessiveabrasionorwear,orhoseiscut,replacewithhose
assemblylistedonpartslistbeforeusingheater.
8. Forindooruseonly.Areamustbewellventilated.Figure 1.
(alsosee"OperatingPrecautions").
9. Ifatanytimegasodorisdetected,IMMEDIATELY
DISCONTINUEoperationuntilthesourceofgashasbeen
locatedandcorrected.ReadenclosedOdorfadeandPropane
Sheetforadditionalinformationaboutdetectingpropane
leaks.
10. Installtheheatersuchthatitisnotdirectlyexposedtowater
spray,rainand/ordrippingwater.
11. Maintainminimumclearancefromnormalcombustiblematerial
(likepaper).Figure 2.
12. Duetothehighsurfaceandexhausttemperatures,adultsand
childrenmustobserveclearancestoavoidburnsorclothing
ignition.
13. Operateonlyonastable,levelsurface.
14. Donotusewithductwork.Donotrestrictinletorexit.
15. Useonlytheelectricalpowerspecified.Theelectrical
connectionandgroundingmustcomplywithNationalElectrical
Code-ANSI/NFPA70(USA)andCGAC22.1Canadian
ElectricalCode,Part1(Canada).
16. Useonlyaproperlygrounded3-prongreceptacleorextension
cord.
17. Donotmove,handleorservicewhilehotorburning.
18. Donotadjusttheheatercombustiontubeelevationwhile
heaterisrunningorhot.Adjustmentstoelevationshouldonly
bemadeaftertheheaterhascooledtotouch.
19. Useonlyinaccordancewithlocalcodesor,intheabsenceof
localcodes,withtheStandardfortheStorageandHandling
ofLiquefiedPetroleumGasesANSI/NFPA58andCGAB149.1,
NaturalGasandPropaneInstallationCode.
Figure 2: MINIMUMCLEARANCE:Fromnormalcombustiblematerials
Clearance
Fromfloor . ......................................................0ft
Fromoutlet . ....................................................6ft
Fromsides......................................................2ft
Fromtop . ........................................................3ft
Locate10ft.fromcanvasorplastictarpaulinsorsimilar
coveringsandsecurethemtopreventflappingormovement
duetowindaction.
3
Operating Instructions and Owner's Manual
ForcedAir170FQAVT