NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
SIZE AND CAPACITY OF PROPANE
CYLINDERS
The­charts­below­show­the­approximate­size­of­the­cylinder­
required­for­these­heaters.­­To­use­the­chart:
1.­­ Select­the­lowest­air­temperature­expected­(at­the­bottom­of­
the­chart).
2.­ Move­straight­up­to­time­of­operation­desired­
(left­side­of­the­chart).
3.­ Read­the­cylinder­size­required.
All­heaters­should­have:­
­
­
HOW MUCH HEAT DO I REQUIRE?
For­economy,­it­is­important­to­match­input­to­that­required.­But­
heat­requirements­often­vary.­For­example,­it­usually­takes­a­lot­
more­heat­to­get­things­warm­than­it­does­to­keep­them­that­
way.­Likewise,­outside­air­temperature­usually­changes­during­
the­day­so­you­may­need­more­heat­at­night­than­you­do­in­the­
daytime.­An­approximation­of­the­heat­required­can­be­found­by­
using­the­chart­below.
BTU'S PER HOUR REQUIRED
Cubic feet
Temperature Rise Required (
of space to
be heated
20
o
­ ­­5,000­
14,000­
­ ­­7,000­
19,000­
­ ­10,000­
27,000­
­ ­15,000­
40,000­
­ ­20,000­
54,000­
­ ­30.000­
80,000­­­­­­­120,000­­­­­­­­160,000­­­­­­­­­200,000
­ ­50,000­­­­­­­­­­­­­­­­133,000­­­­­­­200,000­­­­­­­­266,000­­­­­­­­­­333,000
full­cylinders
good­air­circulation
no­frost­on­cylinders
Fuel­Cyclinder­Capacity:­100#
F)*
o
30
40
50
o
o
o
20,000­
27,999­
34,000
28,000­
38,000­
47,000
40,000­
54,000­
67,000
60,000­
80,000­­­­­­­100,000
80,000­­­­­­­107,000­­­­­­­­­133,000
Operating Instructions and Owner's Manual
WARNING: When­using­a­thermostat­controlled­heater,­
its­ exit­ area­ should­ be­ protected­ from­ personnel­ and­
warnings­posted­of­sudden­startup.
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V
Amps.
­ ­­5-6­
­ ­­6-8­
­ ­­8-12­
­ 10-12­
­ 12-14­
WIRING DIAGRAM
B
GAS
VALVE
W
CHASSIS
GROUND
B
MOTOR
B
CHASSIS
GROUND
R
THERMOSTAT
B
LINE­CORD
CHASSIS
GROUND
COLOR­CODE
B-BLACK
L-BLUE
G-GREEN
If­any­original­wiring­as­supplied­by­the­heater­must­be­replaced,­
it­must­be­replaced­with­type­AWG­105°­C­wire­or­its­equivalent­
except­as­indicated­(*type­SF2-200,­**SGI­250°­C).
170QFAVT - WIRING CHART
COLOR
LENGTH
White­
­
7"­
Black­
­
6"­
Red-(Hi-Temp)­
16­1/2"­
Red-(Hi-Temp)­
16­1/2"­
Orange­ ­
1 1"­
­
­
­
Green­
­
7"­
­
­
­
Red­
­
7"­
­
­
­
White­
­
6"­
­
­
­
Black­
­
6"­
­
­
­
6
Force-Air Propane Construction Heater
Cord Length in Feet
25
50
100
150
18­
16­
14­
­12
18­
16­
12­
­10
18­
14­
12­
­10
16­
14­
10­
­­­8­
16­
12­
10­
­­­8
SPARK­PLUG
B
LINE
HIGH-LIMIT
Y
VALVE
Y
NEUT
R
W
GRD
FLAME­CONTROL
W
G
CHASSIS
GROUND
O-ORANGE
R-RED
W-WHITE
Y-YELLOW
FROM
TO
Valve­­
Terminal­Block
On/Off­Switch­
Terminal­Block
High­Limit­Switch­
Valve­
High­Limit­Switch­
Terminal­Block
Flame­Control­­
Spark­Plug
(Ignition)­
­
Flame­Control­
Ground
(Harness)­
Flame­Control­­
Terminal­Block
(Harness)
Flame­Control­
Terminal­Block
(Harness)
Flame­Control­
Terminal­Block
(Harness)­
G
CHASSIS
GROUND

Publicité

Chapitres

Table des Matières
loading

Table des Matières