8.2 Removing the dome cover

Camera focus is set in the factory. Normally, no further adjustment is required. Therefore, under normal
conditions, the dome cover should not be removed. The dome cover can only be removed after the dome has
been demounted from the mounting plate. Please follow the instructions above to demount the dome before
attempting to remove the dome cover.
Carefully remove the three rubber feet from the dome base plate by peeling them towards the outer edge of the
dome. Place them in a safe location. With the feet removed it can be seen that the design of the metal base
plate allows access to the dome cover retention clips. Use a flat-blade screwdriver or similar to carefully ease
the retention clips away from the edge of the dome base while at the same time applying firm downward
pressure. When the three clips are clear of their retaining lugs, carefully remove the dome base leaving the
dome cover sitting in its packaging. Sit the dome upside-down in its position in the packaging and immediately
refit the three rubber feet.
Do not attempt to manually move the dome mechanism. This can damage the dome and will invalidate
the warranty.

9 Power supply requirements

The product is designed for connection to a 12-24 V
supplying at least 4VA. Failure to connect the product to the required power source will affect product operation,
may result in damage to the product and will void the product warranty.
Do not apply power until all connections are completed and the dome is properly mounted!
It is also possible to buy OMDPSWR power supply kit. This kit includes: 1 switching wide range power supply
=
12V
15W and also a series of different plug cables.

10 Camera performance adjustments

In most installations, the camera's default setting provide for optimum performance. However, it is possible to
adjust certain performance parameters. Please note: only certain controllers will allow access to these
adjustments.

10.1 Camera reset

The camera can be reset by calling preset 34. (Presets are not lost.)

10.2 Manual brightness control

The camera has the equivalent of an electronic iris. Image brightness can therefore be manually adjusted by
use of the iris controls on certain controllers. Open the iris to increase image brightness and close the iris to
decrease image brightness.

10.3 ALC ON/OFF

The camera has in-built automatic lighting control which can, if necessary, be turned OFF or ON. Factory
default is ON.
Call Preset 81 to turn ALC ON
Call Preset 82 to turn ALC OFF

10.4 AGC ON/OFF

The camera has in-built automatic gain control which can, if necessary, be turned OFF or ON. Factory default is
ON.
Call Preset 83 to turn AGC ON
Call Preset 84 to turn AGC OFF
=
or 12-24V~ 50-60Hz power source capable of