12.1 Fuses replacement
CAUTION! For continued protection against
risk of fire, replace only with same type and
rating of fuse. Fuses must be replaced only
by service personnel.
The used fuse is described below.
FUSES REPLACEMENT
Supply voltage
12Vdc
24Vdc
24Vac, 50/60Hz
Tab. 14
As an alternative, use an approved fuse featuring the
same characteristics.
It is necessary to loosen the screws that secure the
slide to the spacers on the bottom and disconnect
the connectors from the board.
FUS1
Fig. 23
12.2 Slide replacing
It is necessary to loosen the screws that secure the
slide to the spacers on the bottom and disconnect
the connectors from the board.
Fig. 24
30
Fuse (FUS1)
T 2A H 250V 5x20
T 2A H 250V 5x20
T 2A H 250V 5x20
12.3 Replacing the rear cover
plate gasket
In the event of o-ring gasket deterioration replace
it using the gasket supplied. In the absence of the
gasket provided, only use VIDEOTEC original spare
parts.
Replace the gasket being careful to insert it correctly
into its housing.
Fig. 25
12.4 Replacement of the wiper
blade
In models equipped with a wiper, the worn blades
can be replaced.
Unscrew the rivet nut fastening the blade and
remove it. Replace the worn blade with a new one.
Re-position the rivet nut adjusting fastening until
the blade correctly adheres to the glass. Activate the
wiper to check the blade is correctly adjusted.
Fig. 26
MNVCMVXTHD_1813_EN