reverse order.
REPLACING THE PILOT BURNER NOZZLE
- Open the door.
- Undo connector R.
- Remove nozzle UP and replace it with the one
indicated in table TAB1.
- Retighten connector R. Reassemble all parts.
- Following, in reverse order, the sequence used for
their removal.
9.

COMMISSIONING

Following installation, conversion to a different type
of gas or any maintenance operations, check
appliance operation. In the event of any malfunction,
consult the next Paragraph " Troubleshooting " .
GAS APPLIANCES
Switch on the appliance as directed in the instructions
and reminders for use given in Chapter "
INSTRUCTIONS FOR USE " and check:
- the gas supply pressure (see next Paragraph).
- the correct ignition of the burners and the
effectiveness of the fumes removal system.
CHECKING THE GAS SUPPLY PRESSURE
- To measure the gas supply pressure use a manometer
with a minimum definition of 0,1 mbar.
- Remove the control panel.
- Remove the screw from on pressure test point PP and
connect the manometer to the test point.
- Make the measurement with the appliance in
operation.
IMPORTANT!
PRESSURE IS NOT WITHIN THE LIMITS
(MIN. - MAX) INDICATED IN TABLE TAB2,
CEASE OPERATION OF THE APPLIANCE
AND
CONTACT
COMPANY.
- Disconnect the manometer and retighten the
retaining screw on the pressure connection.
ELECTRIC EQUIPMENT
Switch on the appliance as directed in the instructions
and reminders for use given in Chapter "
INSTRUCTIONS FOR USE " and check:
- the current values of each phase.
- the correct operation of the heating elements.

INSTRUCTIONS FOR USE

III.
IF
THE
GAS
SUPPLY
THE
GAS
UTILITY
10.

REMINDERS FOR THE USER

READ THIS MANUAL CAREFULLY. IT
PROVIDES IMPORTANT INFORMATION
FOR SAFE INSTALLATION, USE AND
MAINTENANCE OF THE APPLIANCE.
THE MANUFACTURER WILL NOT BE
LIABLE FOR ANY DAMAGE OR INJURY
RESULTING
OBSERVING THE FOLLOWING RULES.
For after-sales service, contact technical assistance
centres authorized by the manufacturer and demand
the use of original spare parts.
Have the appliance serviced at least twice a year. The
manufacturer recommends taking out a service
contract.
The appliance is designed for professional use and
must be operated by trained personnel.
The appliance is to be used for cooking food as
specified in the prescriptions for use. Any other use is
considered to be improper.
Do not allow the appliance to operate empty for
prolonged periods. Only pre-heat the oven just
before use.
Do not leave the appliance unattended while in
operation.
In the event of an appliance fault or malfunction, shut
the gas shut-off valve and/or switch the appliance off
at the main switch installed upline.
Clean the appliance following the instructions given in
Chapter " INSTRUCTIONS FOR CLEANING".
DO NOT STORE " AMMABLE MATERIALS
IN CLOSE PROXIMITY TO THE APPLIANCE.
FIRE HAZARD.
Do not obstruct any air vents or drains present on the
appliance.
Do not tamper with appliance components.
Keep this manual in a safe place, known to all users,
so that it can be consulted throughout the working
life of the appliance.
Installation and appliance maintenance must be
carried out by qualified technicians authorized by the
manufacturer, in compliance with current safety
standards and the instructions in this manual.
Appliance maintenance and conversion to a different
type of gas must be carried out by qualified
technicians authorized by the manufacturer, in
compliance with current safety standards and the
instructions in this manual.