4.4
Connecting the pipes
If no ventilation takes place through the cover, a separate
ventilation pipe must be laid (via the roof).
Fit the sockets:
Check whether the seal is in the socket.
Insert the socket mating part into the pre-drilled opening
from the inside.
Screw the socket hand-tight onto the mating part so that
tightness is guaranteed.
Push the pipe in.
Carry out these steps again for further pipes.
34 / 136
Drill and fit additional pipes (max. DN 70) if necessary
Additional connections (additional inlets, conduit pipes,
ventilation pipes) must be made at least at the height of
the pre-drilled inlets and with a minimum distance of 10
cm between each other.