4.2
Deeper installation
For deeper installation in the floor slab, an additional exten-
sion section (art. no. 830070) must be fitted between the
upper section and the drain body. A maximum installation
depth of 650 mm to the top surface of the functional unit (e.g.
the pump) should be observed for the installation in the floor
slab. This way, the necessary parts can be reached for main-
tenance and servicing.
016-083
4.3
Install the flap housing
Clip on the connecting sockets.
clips latch into the locking device simultaneously).
Check whether the rotating fastener is locked in place.
Lift the quick-release closure.
(Ensure that both