Fault
SPN
FMI
Code
1257
1563
2
1411
4182
3
1412
4183
3
1418
4184
3
1427
4185
31
1428
4186
31
1429
4187
31
1431
4188
31
1432
4223
31
1515
91
19
1539
1387
3
1548
657
5
1549
658
5
1551
660
5
1552
661
5
1553
662
5
1554
663
5
1555
664
5
Diesel Engine Failure-Codes chart
SPN
Lamp
Description
Incompatible
Red
Monitor/Controller
Amber
Amber
Amber
Overspeed
Amber
Shutdown Relay
Driver
Low Oil Pressure
Amber
Shutdown Relay
Driver
High Engine
Amber
Temperature Shut-
down Relay Driver
Pre-Low Oil
Amber
Pressure Indicator
Relay Driver
Pre-High Engine
Amber
Temperature Warn-
ing Relay Driver
Accelerator Pedal
Red
Position 1
Auxiliary
Amber
Pressure #1
Engine Injector
Amber
Cylinder #7
Engine Injector
Amber
Cylinder #8
Engine Injector
Amber
Cylinder #10
Engine Injector
Amber
Cylinder #11
Engine Injector
Amber
Cylinder #12
Engine Injector
Amber
Cylinder #13
Engine Injector
Amber
Cylinder #14
Cumins Description
Control Module Identification Input
State Error - Data erratic, intermittent or incorrect
Generator Output Frequency Adjust
Potentiometer Circuit - Voltage above normal, or shorted to high
source
Droop Adjust Potentiometer Circuit -
Voltage above normal, or shorted to high source
Gain Adjust Potentiometer Circuit -
Voltage above normal, or shorted to high source
Overspeed Shutdown Relay Driver
Diagnostic has detected an error - Condition Exists
Low Oil Pressure (LOP) Shutdown
Relay Driver Diagnostic has detected an error - Condition Exists
High Engine Temperature (HET)
Shutdown Relay Driver Diagnostic has detected an error - Condition
Exists
Pre-Low Oil Pressure Warning Relay Driver Diagnostic has detected
an error - Condition Exists
Pre-High Engine Temperature
Warning Relay Driver Diagnostic has detected an error - Condition
Exists
SAE J1939 Multiplexed Accelerator
Pedal or Lever Sensor System - Received Network Data In Error
Auxiliary Pressure Sensor Input 1
Circuit - Voltage above normal, or shorted to high source
Injector Solenoid Driver Cylinder 7
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 8
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 10
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 11
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 12
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 13
Circuit - Current below normal or open circuit
Injector Solenoid Driver Cylinder 14
Circuit - Current below normal or open circuit