ENGLISH
1. GENERAL SAFETY CONSIDERATIONS FOR ARC WELDING ......................................................5
2. INTRODUCTION AND GENERAL DESCRIPTION ...........................................................................6
2.1 MAIN CHARACTERISTICS .........................................................................................................6
2.2 STANDARD ACCESSORIES ......................................................................................................6
2.3 OPTIONAL ACCESSORIES ........................................................................................................6
3. TECHNICAL DATA.............................................................................................................................6
3.1 DATA PLATE ................................................................................................................................6
3.2 OTHER TECHNICAL DATA: ........................................................................................................7
4. DESCRIPTION OF THE WELDING MACHINE . ................................................................................7
4.1 CONTROL, ADJUSTMENT AND CONNECTION DEVICES. ......................................................7
4.1.1 WELDING MACHINE (Fig. B1, B2, B3) .............................................................................7
4.1.2 WIRE FEEDER UNIT (Fig. B3) .........................................................................................7
4.1.3 WELDING MACHINE CONTROL PANEL (Fig. C) ............................................................7
5. INSTALLATION . .................................................................................................................................7
5.1 POSITIONING THE WELDING MACHINE..................................................................................7
5.2 CONNECTION TO THE MAIN POWER SUPPLY .......................................................................7
5.2.1 Plug and outlet ...................................................................................................................7
5.3 WELDING CIRCUIT CONNECTION ...........................................................................................7
5.3.1 Recommendations .............................................................................................................7
5.3.2 WELDING CIRCUIT CONNECTION IN MIG-MAG MODE ...............................................7
5.3.2.1 Connecting the gas bottle (if used) ......................................................................7
5.3.2.2 Connecting the welding current return cable .......................................................7
5.3.2.3 Torch (Fig. B)........................................................................................................7
5.3.3 WELDING CIRCUIT CONNECTIONS IN TIG MODE .......................................................7
5.3.3.1 Gas cylinder connection .......................................................................................7
5.3.3.2 Connecting the welding current return cable .......................................................8
5.3.3.3 Torch ....................................................................................................................8
5.3.4 WELDING CIRCUIT CONNECTIONS IN MMA MODE .....................................................8
5.3.4.1 Connection of the electrode-holder clamp welding cable ....................................8
5.3.4.2 Connecting the welding current return cable .......................................................8
5.4 LOADING THE WIRE SPOOL (Fig. G1, G2) ...............................................................................8
5.5 REPLACING THE TORCH WIRE GUIDE SHEATH (FIG. H) ......................................................8
5.5.1 Spiral sheath for steel wire ................................................................................................8
5.5.2 Synthetic sheath for aluminium wire ..................................................................................8
6. MIG-MAG WELDING: PROCESS DESCRIPTION . ...........................................................................8
CONTINUOUS WIRE WELDING MACHINE FOR MIG-MAG AND FLUX, TIG, MMA
WELDING FOR PROFESSIONAL AND INDUSTRIAL USE.
Note: The term "welding machine" will be used in the text that follows.
1. GENERAL SAFETY CONSIDERATIONS FOR ARC WELDING
The operator should be properly trained to use the welding machine safely
and should be informed about the risks related to arc welding procedures, the
associated protection measures and emergency procedures.
(Please refer to the applicable standard "EN 60974-9: Arc welding equipment.
Part 9: Installation and Use).
- Avoid direct contact with the welding circuit: the no-load voltage supplied by
the welding machine can be dangerous under certain circumstances.
- When the welding cables are being connected or checks and repairs are
carried out the welding machine should be switched off and disconnected
from the power supply outlet.
- Switch off the welding machine and disconnect it from the power supply outlet
before replacing consumable torch parts.
- Make the electrical connections and installation according to the safety rules
and legislation in force.
- The welding machine should be connected only and exclusively to a power
source with the neutral lead connected to earth.
- Make sure that the power supply plug is correctly connected to the earth
protection outlet.
- Do not use the welding machine in damp or wet places and do not weld in the
rain.
- Do not use cables with worn insulation or loose connections.
- If a liquid cooling unit is present, filling operations must be carried out with the
welding machine off and disconnected from the power supply.
- Do not weld on containers or piping that contains or has contained flammable
liquid or gaseous products.
- Do not operate on materials cleaned with chlorinated solvents or near such
substances.
- Do not weld on containers under pressure.
- Remove all flammable materials (e.g. wood, paper, rags etc.) from the working
area.
- Provide adequate ventilation or facilities for the removal of welding fumes near
the arc; a systematic approach is needed in evaluating the exposure limits for
the welding fumes, which will depend on their composition, concentration and
the length of exposure itself.
- Keep the gas bottle (if used) away from heat sources, including direct sunlight.
- Use electric insulation that is suitable for the torch, the workpiece and any
metal parts that may be placed on the ground and nearby (accessible).
This can normally be done by wearing gloves, footwear, head protection and
clothing that are suitable for the purpose and by using insulating boards or
mats.
- Always protect your eyes with the relative filters, which must comply with UNI
INDEX
page
6.1 SHORT ARC ................................................................................................................................8
7. MIG-MAG OPERATION MODEE . ......................................................................................................8
7.1 Operating in manual mode ..........................................................................................................8
7.2 Synergic operating mode .............................................................................................................8
7.2.1 ATC Mode (Advanced Thermal Control) ............................................................................8
7.2.2 Advanced parameter setting: MENU 1 (Fig I-4) .................................................................8
7.3 Insertion of remote command (on request) .................................................................................9
8. CONTROLLING THE TORCH PUSH-BUTTON ................................................................................9
8.1 Setting the torch push-button control mode (Fig. l-5) ..................................................................9
8.2 Torch push-button control mode ..................................................................................................9
9. INFO MENU .......................................................................................................................................9
10. UNIT OF MEASUREMENT MENU ..................................................................................................9
11. CALIBRATION MENU . .....................................................................................................................9
12. G.R.A. DISABLING MENU (AQUA version only). .........................................................................9
13. MMA WELDING: PROCESS DESCRIPTION . .................................................................................9
13.1 GENERAL PRINCIPLES ...........................................................................................................9
13.2 PROCEDURE ............................................................................................................................9
13.3 MMA mode setting ....................................................................................................................9
13.4 Insertion of remote command (on request) ...............................................................................9
14. TIG DC WELDING: PROCESS DESCRIPTION . .............................................................................9
14.1 GENERAL PRINCIPLES ...........................................................................................................9
14.2 PROCEDURE (LIFT STRIKE) ...................................................................................................9
14.3 LCD DISPLAY IN TIG MODE (Fig. L-12) .................................................................................10
14.4 Insertion of remote command (on request) .............................................................................10
15. ALARM SIGNALS (TAB. 8) ...........................................................................................................10
16. JOBS MENU ..................................................................................................................................10
16.1 Save procedure (SAVE). .........................................................................................................10
16.2 Retrieval procedure of a customised program ........................................................................10
17. MAINTENANCE . ...........................................................................................................................10
17.1 ROUTINE MAINTENANCE: ....................................................................................................10
17.1.1 Torch ..............................................................................................................................10
17.1.2 Wire feeder ....................................................................................................................10
17.2 EXTRAORDINARY MAINTENANCE .......................................................................................10
18. TROUBLESHOOTING (TAB. 8) ....................................................................................................10
EN 169 or UNI EN 379, mounted on masks or use helmets that comply with UNI
EN 175.
Use the relative fire-resistant clothing (compliant with UNI EN 11611) and
welding gloves (compliant with UNI EN 12477) without exposing the skin to the
ultraviolet and infrared rays produced by the arc; the protection must extend
to other people who are near the arc by way of screens or non-reflective
sheets.
- Noise: If the daily personal noise exposure (LEPd) is equal to or higher than 85
dB(A) because of particularly intensive welding operations, suitable personal
protective means must be used (Tab. 1).
- The flow of the welding current generates electromagnetic fields (EMF) around
the welding circuit.
Electromagnetic fields can interfere with certain medical equipment (e.g. Pace-
makers, respiratory equipment, metallic prostheses etc.).
Adequate protective measures must be adopted for persons with these types of
medical apparatus. For example, they must be forbidden access to the area in
which welding machines are in operation.
This welding machine conforms to technical product standards for exclusive
use in an industrial environment for professional purposes. It does not assure
compliance with the basic limits relative to human exposure to electromagnetic
fields in the domestic environment.
The operator must adopt the following procedures in order to reduce exposure
to electromagnetic fields:
- Fasten the two welding cables as close together as possible.
- Keep head and trunk as far away as possible from the welding circuit.
- Never wind welding cables around the body.
- Avoid welding with the body within the welding circuit. Keep both cables on
the same side of the body.
- Connect the welding current return cable to the piece being welded, as close
as possible to the welding joint.
- Do not weld while close to, sitting on or leaning against the welding machine
(keep at least 50 cm away from it).
- Do not leave objects in ferromagnetic material in proximity of the welding
circuit.
- Minimum distance d= 20 cm (Fig. Q).
- Class A equipment:
This welding machine conforms to technical product standards for exclusive
use in an industrial environment and for professional purposes. It does not
assure compliance with electromagnetic compatibility in domestic dwellings
and in premises directly connected to a low-voltage power supply system
feeding buildings for domestic use.
EXTRA PRECAUTIONS
- WELDING OPERATIONS:
- 5 -
page