Mounting and
operating instructions
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.15
Lock and unlock keys
Command (Byte 3): decimal 86; hexadecimal 0x56
Parameter:
D0 = 0: key lock inactive
D0 = 1: key lock active
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The keys on the sensor are locked or unlocked.
Example telegram
(in the example, the sensor has the address 1, the key lock is active)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.16
Permanent storage of configurations
Command (Byte 3): decimal 83; hexadecimal 0x53
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Sensor settings are stored in the EEPROM (they thus remain saved even after the power supply has been discon-
nected).
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4 Byte
Check sum
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
Decimal
Hex.:
129
81
4
04
87
57
82
52
Decimal
Hex.:
129
81
5
05
86
56
1
01
83
53
Decimal
Hex.:
129
81
4
04
83
53
86
56
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
7 bit data byte
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Decimal
Hex.:
129
81
4
04
89
59
92
5C
Decimal
Hex.:
129
81
4
04
89
59
92
5C
Decimal
Hex.:
129
81
4
04
89
59
92
5C
73