Minimum-Hold" Function (With Q1 As Control Input); Difference Hold" Function (With Q1 As Control Input); Activate Factory Setting - Balluff BOD 26K LB04-S115-C Instructions De Service Et De Montage

Capteur de distance
Masquer les pouces Voir aussi pour BOD 26K LB04-S115-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.5.12
„Minimum-Hold" function (with Q
Command (Byte 3): decimal 77; hexadecimal 0x4D
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
When Q
= +U
, the min. recorded measured value is stored. If Q
1
B
„Operating measured values".
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.13
„Difference Hold" function (with Q
Command (Byte 3): decimal 68; hexadecimal 0x44
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Provided Q
= +U
, the difference between the measured values is saved. When Q
1
B
transmitted at the analogue output.
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.14

Activate factory setting

Command (Byte 3): decimal 87; hexadecimal 0x57
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
The sensor is reset to factory setting.
72
Decimal
Hex.:
129
81
4
04
77
4D
72
48
Decimal
Hex.:
129
81
4
04
68
44
65
41
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
as control input)
1
-U
, the minimum value can be called up via
1 =
B
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
as control input)
1
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Mounting and
operating instructions
Decimal
129
4
89
92
-U
, the determined value is
1 =
B
Decimal
129
4
89
92
Hex.:
81
04
59
5C
Hex.:
81
04
59
5C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bod 26k lbr04-s115-cBod 26k lb05-s115-cBod 26k lbr05-s115-c

Table des Matières