Balluff BOD 26K LB04-S115-C Instructions De Service Et De Montage page 53

Capteur de distance
Masquer les pouces Voir aussi pour BOD 26K LB04-S115-C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting and
operating instructions
No. Action
Picture
follows
15 Switch on 40 ms averaging:
Q
Q
1
OK
I
C
FA
push
14x
16 Scaling the analogue output (set 4 mA point):
Q
Q
1
OK
I
C
FA
push
15x
17 Scaling the analogue output (set 20 mA point):
Q
Q
1
I
OK
C
FA
push
16x
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
Action
Reaction / Status indicator „ZA" (red)
Switch with
ON, if active
2
OFF, if inactive
SET
The last (max.) 100 measured values are used to form the average. For an explanation on
„Averaging" see function no. 13
Save mea-
ON, when object is within the measuring range
2
sured value
OFF, when object is outside the measuring
range
SET
with
SET
Once the
key has been activated, the current measured value corresponds with the 4
mA point of the analogue output. The incline of the output characteristics results from this
point and the 20 mA point (function no. 17). Should no object be present in the detection
range, the end of the measuring range is used.
Save mea-
ON, when object is within the measuring range
2
sured value
OFF, when object is outside the measuring
range
SET
with
SET
Once the
key has been activated, the current measured value corresponds with the
20 mA point of the analogue output. The incline of the output characteristics results from
this point and the 4 mA point (function no. 16). Should no object be present in the detec-
tion range, the end of the measuring range is used
Factory setting
Averaging 40 ms OFF
(„ZA" = OFF)
4 mA = end of measuring
range
20 mA = end of measu-
ring range
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bod 26k lbr04-s115-cBod 26k lb05-s115-cBod 26k lbr05-s115-c

Table des Matières