8.4

Overview of master commands:

Command description Dec.
Set switching output Q
Set switching output Q
Set Q
as output
2
„Good Target"
Set Q
as Trigger input
1
Set Q
as control input
1
for laser ON/OFF
Averaging
Scaling analogue
output (4 mA)
Scaling analogue
output (20 mA)
„Autom. zero" function
(with Q
as control
1
input)
Autom. centre" (with Q
as control input)
„Maximum Hold" func-
tion (with Q
as control
1
input)
Minimum Hold" function
(with Q
as control
1
input)
„Difference Hold" func-
tion (with Q
as control
1
input)
Activate factory setting
64
Hex.:
ASCII Remark
49
31
1
1
50
32
2
2
71
47
G
84
54
T
69
45
E
66
42
B
78
4E
N
72
48
H
90
5A
Z
67
43
C
1
88
58
X
77
4D
M
68
44
D
87
57
W
Switching output Q
is set:
1
1st and 2nd switching point
N.C / N.O.
Pulse stretching
Switching output Q
is set:
2
1st and 2nd switching point
N.C / N.O.
Pulse stretching
Q
switches when an object is in the measuring range
2
(Good Target).
Q
is set as trigger input. With rising edge on Q
1
measured value is held until the next trigger occurs.
Used to switch laser beam on and off.
Q
= +U
(laser beam ON),
1
B
Q
= -U
(laser beam OFF).
1
B
Last measured value remains. When reactivated, the
response time is prolonged according to the set mean
value.
The number of meas. values used for averaging
(arithmetic mean) is set (1 / 10 / 100 meas. values).
The transmitted value is set as 4 mA point at analo-
gue output.
The transmitted value is set as 20 mA point at analo-
gue output.
The output characteristics 4 ... 20 mA are displaced.
If Q
= +U
the current measured value is set as the
1
B
analogue value 4 mA. The incline of the characteri-
stics is maintained. The max. value of the characteri-
stics is limited by the measuring range.
The output characteristics 4 ... 20 mA are displaced.
If Q
= +U
the current measured value is set as the
1
B
analogue value 12 mA. The incline of the characte-
ristics is maintained. The min. or max. value of the
characteristics are limited by the measuring range.
Provided Q
= +U
, the max. recorded measured
1
B
value is stored. If Q
= -U
1
transmitted at the analogue output or can be called up
via „Measured operating values".
Provided Q
= +U
, the min. recorded measured
1
B
value is stored. If Q
= -U
1
transmitted at the analogue output or can be called up
via „Measured operating values".
Provided Q
= +UB, the difference between the mea-
1
sured values is saved. If Q
value is transmitted at the analogue output or can be
called up via „Measured operating values".
The sensor resets all settings to the factory setting
incl. sensor address.
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
Mounting and
operating instructions
,
1
, the determined value is
B
, the determined value is
B
= -U
, the determined
1
B
Example
8.5.1
8.5.2
8.5.3
8.5.4
8.5.5
8.5.6
8.5.7
8.5.8
8.5.9
8.5.10
8.5.11
8.5.12
8.5.13
8.5.14