8.5.17
Set Q
input
1
Command (Byte 3): decimal 81; hexadecimal 0x51
Parameter:
D0 = 0: set Q
D0 = 1: set Q
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Q
input is set via the software. The functions which depend on the status of the input (e.g. Q1 as trigger input or
1
autom. zero) can thus be controlled via the software.
Example telegram
(in the example, the sensor has the address 1, Q
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Data
5. Byte
Check sum
8.5.18
Measured distance values
Command (Byte 3): decimal 65; hexadecimal 0x41
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
Data
Reads out the current distance to the object (raw data). Altered characteristic settings (4 mA point, 20 mA point, Min,
Max, autom. centre ...) are not taken into account. The analogue output is not affected, it always transmits measured
operating values.
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
74
low
1
high
1
is set to high)
1
Decimal
Hex.:
129
81
5
05
81
51
1
01
84
54
Decimal
Hex.:
129
81
4
04
65
41
68
44
No. 834826 E Edition 1310; Replaces edition 1111; Subject to modification
Parameter format
7 bit data byte
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
12 bit data item Data 3
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Data
5. Byte
6. Byte
Check sum
Mounting and
operating instructions
Decimal
Hex.:
129
81
4
04
89
59
92
5C
Decimal
Hex.:
129
81
6
06
89
59
64
40
0
00
30
1E