Installation Conditions For The Outdoor Version - Häfele DT 600c Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70

4.6 Installation conditions for the outdoor version

The 'Outdoor version' specification requires that the interior module is located in the
protected indoor area. The exterior module is located in the outdoor area.
Outdoor installation of the interior module is not permitted!
Component
Door panel
maintenance
Ambient temperature
Water
Resistance to dust
Installation reference
• Only the outdoor version of the DT 600c FH may be mounted on
fire resistant doors.
Carry out the following measures after 24 months of operation at
the latest to ensure the specified protection:
• Check the seal on the back of the housing against the door leaf
• Check/replace the silicone seal.
• Exterior module: -10 – 55°C
Attention:
• If exterior modules are exposed to the weather, there is a risk that
the profile cylinder will get wet, freeze and may no longer be
usable for an emergency opening.
• Please note the specifications of the profile cylinder manufacturer
regarding water compatibility!
• The interior module has no protection against water/moisture and
therefore must not be installed outdoors or in wet rooms.
• Please note the specifications of the profile cylinder manufacturer
regarding resistance to dust!
45

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dt 600c fh

Table des Matières