Häfele DT 600c Instructions D'utilisation page 67

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
A sticker with the inscription 'Operate lever handle to open' or a pictogram should be placed
on the inside of the door immediately above the operating device or on the operating device
itself (see sample below).
With type 'B' panic exit devices, intended for use on emergency exit doors opening inwards, a
sticker with the inscription 'Pull lever handle to open' or a pictogram should be placed on the
inside of the door immediately above the pull plate. The surface of the pictogram should be at
least 8,000 mm² and the colours white on a green background.
14.4 Additional requirements of panic exit devices if they are used on smoke control /
fire protection doors in compliance with EN 179
Restriction of intended use of the DT 600c FH with EN 179:
• Only for single doors
• Escape direction for inward and outward opening doors
• Version for rebated door
• The max. permissible door weight is 200 kg.
• The max. permissible deformation of the door leaf to the rebate is 3 mm.
The safety features of this product are an essential requirement for its compliance with
EN 179.
No modifications must be made, unless they are described in the instructions.
DANGER
Risk caused by key inside the profile cylinder!
If there is a key inside the profile cylinder that ist not removed, there is risk of
malfunctions.
• The key of the profile cylinder must always be removed.
• The profile cylinder is for emergency opening only.
Planning may only be carried out by DIALOCK specialists.
Door fittings for fire resistant and smoke control doors, e.g. the DT 600c FH door
terminal, must be approved by the door manufacturer. If the terminal is installed
without this approval, the Fire and Smoke Control Certificate for the fire resistant or
smoke control door will be invalidated.