Electrical Wire Diagram - Pit Boss PRO Serie Assemblage Et Fonctionnement

Masquer les pouces Voir aussi pour PRO Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60Hz, 275W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
FUEL INPUT
RATING:
2.0 KG/H
(4.4 LB/H)
GROUNDED POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
IGNITOR ASSEMBLY /
HD CARTRIDGE HEATER
200W, 120V,
0.375 X 5.0 IN. / 9.5 X 127MM
INDEX
K : BLACK
W : WHITE
R : RED
Y : YELLOW
P : PURPLE
O : ORANGE
G : GREEN
28

ELECTRICAL WIRE DIAGRAM

LOCATE AND REMOVE
THE EIGHT SCREWS
OF ACCESS PANEL ON
UNDERSIDE OF UNIT
GROUND
G
W
P
R
R
AUGER MOTOR
& FEED SYSTEM
120V, 50/60Hz, 2 RPM
MOTOR
CONTROL BOARD
K
K
R
W
o
W
Y
GRILL PROBE
W
LIGHT
25W, 120V
Y
DRAFT FAN
120V, 50/60Hz,
1 PHASE