WIRING DIAGRAMS & ELECTRICAL GUIDELINES
WARNING: To reduce the risk of electric shock, wiring should be performed by a qualified electrician!
Incorrect assembly can cause electric shock or damage the motor and the controller! Hazard of electrical
shock!
WARNING: The installation of a Big Ass Fan must be in accordance with the requirements specified in this
installation manual and with any additional requirements set forth by the National Electric Code (NEC),
ANSI/NFPA 70-2014, and all local codes. Code compliance is ultimately YOUR responsibility!
CAUTION: The product warranty will not cover damage or failure caused by improper installation.
WARNING: Exercise caution and common sense when powering the fan. Do not connect the fan to a
damaged or hazardous power source. Do not attempt to resolve electrical malfunctions or failures on
your own. Contact Big Ass Fans if you have any questions regarding the electrical installation of this fan.
Wiring Diagram
Power Supply
110–125 VAC 1 Φ
10 A 50/60 Hz
Power Supply
Cable
WHITE
GREEN
BLACK
22
Wall Controller
WWW.BIGASSSOLUTIONS.COM
© 2015 DELTA T CORP.
White
Brown
Orange
Yellow
Blue
Green
Red
Black
BLUE
YELLOW
Controller
Input Cable
ALL RIGHTS RESERVED.
Controller Input Cable
+0–10 VDC Speed Ref.
Not Used
Status LED (+)
Run Enable
Closed: Enable; Open: Disable
Status LED (-)
+10 VDC Supply
DC Common
CAT5 Cable
To wall
controller