4 Setup
4.1 Included items
Robin®
•
A Ceiling hoist
including two lifting straps with hooks and an emergency
strap. Robin® Mover also includes the trolley.
•
B Hand control
•
C User manual
4.2 Before Use
CAUTION!
– The ceiling hoist is not intended to be
used together with MEDICAL ELECTRICAL
EQUIPMENT.
Before first use, all features of the hoist system must be
inspected by specialized service technicians.
Perform a visual inspection of the ceiling hoist. If the
packaging is damaged upon arrival, the ceiling hoist parts
must be thoroughly examined for visible damage or defects.
If there is any suspicion of damage, the ceiling hoist must
not be used before specialized service technicians have
approved it.
The emergency stop is activated during shipment. Reset
the emergency stop before first use. See 5.9 Resetting the
emergency stop or lowering feature, page 12.
It is possible that the hoist´s battery is discharged on account
of self-discharge. Charge the hoist´s battery before first use.
See 5.5 Charging the Battery, page 10.
4.3 Installing the ceiling hoist
The ceiling hoist has to be mounted to a rail system for use.
The rail system has to be installed and approved according
to EN 10535 by a specialized dealer or specialized service
technician.
Installing Robin®
The Robin® requires a trolley, holding the ceiling hoist in
the rail system. The trolley has to be pre-installed by a
specialized dealer or service technician.
To mount the ceiling hoist to the trolley, do the following:
1586745-E
Robin® Mover
1. Locate the hoist trolley at the Ø 32 mm round recess
in the rail.
2. Lift the hoist and push the suspension pin through the
trolley opening.
3. Turn the hoist by 90 degrees to fix it in the trolley.
4. Adjust the length of the emergency stop/lowering cord
to within the user's reach.
Installing Robin® Mover
Robin® Mover is a ceiling hoist with the trolley already
attached. The trolley can therefore not be pre-installed in
the rail system.
The ceiling hoist has to be installed by a specialized dealer
or service technician.
4.4 Inserting hand control plug
1. Slide and hold locking lever A away from the aperture
C.
A gate in the aperture will open.
2. Make sure the plug B is in the correct orientation with
the slot upwards (see image). Insert plug into aperture.
3. Release lever, so that the gate closes and hold the plug
in the aperture.
Removing the hand control plug
1. Slide and hold locking lever A away from the aperture
C.
2. Pull the plug B out of the aperture.
3. Release lever.
Setup
9