6. Old style circuit breaker box input 1 & 2 cord and input
3 & 4 cord wiring connections. Skip to Assembly Step
8 if Night-Lite V-Series unit is equipped with an new
style circuit breaker box. Steps for connecting input
wiring are as follows:
a. Locate the neutral isolator (GG, Figure 5a) and
connect the white wire with a ring terminal from each
input cord. Secure the wires to the isolator by using
the nut that was removed in Disassembly Step 2-c.
b. Locate the ground bolt (HH, Figure 5a) and connect
the green wire with a ring terminal from each input
cord. Secure the wires to the ground bolt by using
the nut that was removed in Disassembly Step 2-d.
c. Locate the 2-port lever locks that are connected to
black wires leading from the 725 light relays and
have one port open. Connect the black wire from
the input 1 & 2 cord (II, Figure 5a) to the lever lock
and the black wire from light relay 1. Connect the
red wire from the input 1 & 2 cord (JJ, Figure 5a)
to the lever lock and the black wire from light relay
2. Connect the black wire from the input 3 & 4 cord
(KK, Figure 5a) to the lever lock and the black wire
from light relay 3. Connect the red wire from the
input 3 & 4 cord (LL, Figure 5a) to the lever lock and
the black wire from light relay 4.
d. Secure wires with zip ties (Ref. 10).
7. Old style circuit breaker box output cord and tower
cord wiring connections. Steps for connecting the
ouput and tower wiring are as follows:
a. Remove the ring terminals from the green and
orange wires from the tower cord. Strip insulation
just enough so that the bare wire can be inserted
into a lever lock.
b. Using the four 2-port lever locks that were removed
in Disassembly Step 2-e and the remaining four
EE
of the 2-port lever locks (Ref. 9) from kit contents
connect the output cord wires to the tower cord
wires in the control box. Connect the output cord
red with black stripe wire to the tower cord brown
wire (MM, Figure 5a). Connect the white with black
stripe wire to the yellow wire (NN, Figure 5a).
Connect the blue wire to the blue wire (OO, Figure
5a). Connect the orange wire to the orange wire
(PP, Figure 5a). Connect the red wire to the red
wire (QQ, Figure 5a). Connect the green wire to the
green wire (RR, Figure 5a). Connect the black wire
to the black wire (SS, Figure 5a). Connect the white
EE
wire to the white wire (TT, Figure 5a).
c. Secure wires together with zip ties (Ref. 10).
DD
d. Close up the circuit panel cover (UU, Figure 5b)
on the box. Using the hardware (VV, Figure 5b)
removed in Disassembly Step 2-a, install the cover
onto the circuit breaker box.
5a
Input 1 & 2
Input 3 & 4
I I
SS
Tower
Light Relay 1
Light Relay 3
Light Relay 2
LL
JJ
KK
TT
QQ
RR
PP
OO
Light Relay 4
HH
Output
GG
MM
NN
en