Miscellaneous Commands; Phase Locking Commands; Remote Command Summary - Metrix GX1010 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

∗STB?
∗WAI

5.2.12. Miscellaneous Commands

∗IDN?
∗TST?

5.2.13. Phase Locking Commands

∗TRG
CLOCKBNC <cpd>
ABORT
5.3.

Remote Command Summary

∗ESE <nrf>
∗ESE?
∗ESR?
∗IDN?
∗IST?
∗LRN?
∗PRE <nrf>
∗PRE?
∗RCL <nrf>
∗RST
∗SAV <nrf>
∗SRE <nrf>
∗SRE?
∗STB?
50 - II
Returns the value of the Status Byte Register in <nr1>
numeric format. The syntax of the response is<nr1><rmt>
Wait for operation complete true. As all commands are
completely executed before the next is started this command
takes no additional action.
Returns the instrument identification. The exact response is
determined by the instrument configuration and is of the form
<NAME>,<model>, 0, <version><rmt>where <NAME> is the
manufacturer's name, <MODEL> defines the type of
instrument and <VERSION> is the revision level of the
software installed.
The generator has no self-test capability and the response is
always 0<rmt>
Executes a trigger which will have the same effect as
pressing the MAN/SYNC key. GPIB Group Execute Trigger
command (GET) will perform the same function as
Set clock bnc mode to <OUTPUT>,<INPUT> or <SLAVE>
(phase lock)
Abort on unsuccessful phase locking operation. If no
operation was in progress the command is ignored. If an
operation is aborted then error 136 is placed in the execution
error register.
Set the Standard Event Status Enable Register to the value
of <nrf>.
Returns the value in the Standard Event Status Enable
Register in <nr1> numeric format.
Returns the value in the Standard Event Status Register in
<nr1> numeric format.
Returns the instrument identification.
Returns ist local message as defined by IEEE Std. 488.2.
Returns the complete set up of the instrument as a
hexadecimal character data block approximately 842 bytes
long.
Set the Parallel Poll Enable Register to the value <nrf>.
Returns the value in the Parallel Poll Enable Register in
<nr1> numeric format.
Recalls the instrument set up contained in store number
<nrf>.
Resets the instrument parameters to their default values.
Saves the complete instrument set up in the store number
<nrf>.
Set the Service Request Enable Register to <nrf>. If the
value of <nrf>.
Returns the value of the Service Request Enable Register in
<nr1> numeric format.
Returns the value of the Status Byte Register in <nr1>
numeric format.
∗ ∗ ∗ ∗
TRG.